15 | 17
Appendix
Datasheet
Number of measuring channels:
2 (full bridge resistance >300 Ω)
Supply voltage:
12E - 0 … 18 VDC
24E - 18 … 30 VDC
Electronic protected against reversal voltage
Isolating proof voltage input to
output:
200 V
Higher isolated proof voltage on request
Power consumption:
max. 5 W
Strain gauge excitation supply:
+5 VDC / +10 VDC
Analogue output:
0 … 10 V / ±10 V
4 … 20 mA
max. 1 mA (short-period proof)
max. 500 Ω
Limit frequency (-3 dB):
1 kHz
optional up to 30 kHz
Input resistance:
>3 MΩ
Max. input sensitivity:
100 mV/V at ±5 VDC excitation supply
Non-linearity:
±0.05 % FSO
Electrical connection:
EMC-cable gland on internal terminal block
Enclosure:
EMC-aluminium diecast enclosure (IP66)
Dimension (B x H x D):
220 x 70 x 140 mm
Weight:
approx. 1500 g
Temperature, storage:
-20 °C … +60 °C
Temperature, operating:
-20 °C … +50 °C
Order designation
SG-2K-IP-…
Dual channel strain gauge amplifier in a EMC-aluminum diecast enclosure (IP66)
…-12E-
…
Supply voltage: 10 … 18 VDC
…-
24E-…
Supply voltage: 18… 30 VDC
…-010-
…
Analogue output: 0 … 10 V
…-B10-
…
Analogue output: ±10 V
…-420-
…
Analogue output: 4 … 20 mA
…-GFxx
Limit frequency optionally up to 30 kHz
No declaration (GFxx) for standard version 1 kHz