3–20
Altera Corporation
Stratix GX Transceiver User Guide
January 2005
Basic Mode Clocking
An example would be the invalid code encoding of a K24.1 (
data =
8'h38 + tx_ctrlenable = 1'b1
). Depending on the current running
disparity, the K24.1 can be encoded to be 10'b0110001100 (0x18C), which
is equivalent to a D24.6+ (0xD8 from the RD+ column). An 8B/10B
decoder would decode this value incorrectly.
Basic Mode
Clocking
Two types of clocking are available in basic mode: channel clocking and
inter-transceiver clocking.
Basic Mode Channel Clocking
This section describes internal clocking and the external clocks of the
transceiver in basic mode. By default, the MegaWizard Plug-In Manager
parameterizes the
altgxb
megafunction with the clock configuration
shown in
.
Figure 3–19. Default Configuration of the altgxb Megafunction in Basic Mode
The
altgxb
megafunction (shown in basic mode in
) is
configured such that the train receiver PLL with transmitter PLL is
enabled. The transmitter PLL is fed from an
inclk
port, which itself can
be fed from a dedicated
REFCLKB
, global clock, regional clock, or fast
regional clock source. The receiver logic is clocked by the recovered clock
from the CRU, which is
rx_clkout
. This recovered clock is also fed into
the device so that in a multi-crystal environment, some level of clock
domain decoupling can be implemented to interface with a system clock.
Summary of Contents for Stratix GX
Page 18: ...1 10 Altera Corporation Stratix GX Transceiver User Guide January 2005 Modes of Operation ...
Page 200: ...6 46 Altera Corporation Stratix GX Transceiver User Guide January 2005 Design Example ...
Page 296: ...A 12 Altera Corporation Stratix GX Transceiver User Guide January 2005 8B 10B Code ...
Page 318: ...C 8 Altera Corporation Stratix GX Transceiver User Guide January 2005 Known Issues ...