Altera EN2342QI User Manual Download Page 3

EN2342QI Evaluation Board User Guide 

15) 

Pre-Bias Protection

 – Pre-Bias protection 

is disabled by default on the evaluation 
board. To enable pre-bias protection, 
remove R17 and connect TP33 to AVIN (a 
zero ohm connection may be used). A fast 
ENABLE  signal greater than 3V/100µs must 
be used in order for the Pre-Bias protection 
to work properly.  A signal generator is 
recommended to test this feature. Be sure 
to follow the sequence requirement where 
the 12V rail is in regulation before the 
device is enabled. Refer to the following 
timing diagram or the EN2342QI Datasheet 
for details on Pre-Bias Protection. 

 

 

PVIN

ENABLE

0V

12V

3.3V

0V

VOUT

Soft Start Time ≈ 2ms 

w/Css=47nF

Delay from ENABLE rising

edge to soft start begin

~ 1ms 

Delay from ENABLE falling 

edge to soft shutdown 

begin ~ 1.5ms

Soft Shutdown 

Time ≈ 1.3ms 

w/Css=47nF

PVIN – Recommended 

to be ramped down 

after the Vout soft-

shutdown occurs

PVIN slew rate limitations

as per datasheet

www.altera.com/enpirion

, Page 3 

 