![Altera Cyclone IV Device Handbook Download Page 381](http://html1.mh-extra.com/html/altera/cyclone-iv/cyclone-iv_device-handbook_2910785381.webp)
Chapter 2: Cyclone IV Reset Control and Power Down
2–7
Transceiver Reset Sequences
September 2014
Altera Corporation
Transmitter Only Channel
This configuration contains only a transmitter channel. If you create a
Transmitter
Only
instance in the ALTGX MegaWizard Plug-In Manager in Basic ×4 functional
mode, use the reset sequence shown in
As shown in
, perform the following reset procedure for the
Transmitter
Only
channel configuration:
1. After power up, assert
pll_areset
for a minimum period of 1
s (the time
between markers 1 and 2).
2. Keep the
tx_digitalreset
signal asserted during this time period. After you
de-assert the
pll_areset
signal, the multipurpose PLL starts locking to the
transmitter input reference clock.
3. When the multipurpose PLL locks, as indicated by the
pll_locked
signal going
high (marker 3), de-assert the
tx_digitalreset
signal (marker 4). At this point, the
transmitter is ready for transmitting data.
Figure 2–3. Sample Reset Sequence for Bonded and Non-Bonded Configuration Transmitter Only Channels
Reset and Power-Down Si
g
nals
1
2
1
s
4
Output Status Si
g
nals
3
pll_areset
tx_digitalreset
pll_locked
Summary of Contents for Cyclone IV
Page 10: ...x Chapter Revision Dates Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 14: ...I 2 Section I Device Core Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 274: ...vi Contents Cyclone IV Device Handbook February 2015 Altera Corporation Volume 2...
Page 440: ...iv Contents Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 442: ...vi Chapter Revision Dates Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 446: ......