FX 950 T 

Fuse replacement

Replace the fuses as follows:

-turn the voltage of the power supply unit off;

-remove the cap of the fuse holder;

-replace the fuse with a new one with the same electric 

characteristics;

-check the fuse holder and in case of oxidation or burns,  

replace it;

-reassemble the cap of the fuse holder;

-turn the voltage of the power supply unit on;

Refer to “Fuse specifications” for the value of the fuses.

Connection instructions

I) The power supply unit must necessarily be earthed by 

means of the input earth clamp (central clamp looking 

from the clamp side) with a 2.5mm ² cable;

II) The microwave head must be connected to the power 

supply unit by means of the earth wire (yellow-green) 

provided on either the head and the power supply; for 

safety reasons, another earth wire must be placed on the 

earth terminal on the head.

III) The connections between the head and the power 

supply unit are carried out by means of plugs and 

terminals: do not turn the power supply on if all the 

cables are not correctly connected and fixed in their 

positions.

IV) Apart from the connection cables to the head, the 

connections to RACK POWER UP, ENABLING  signals 

and to the INTERLOCK chain are required (closed 

contact to supply power). If INTERLOCK is not to be 

used, terminals 6 and 7 can be connected together on 

connector J5.

V) Install an external switch in order to disconnect the 

main power supply, to be used each time maintenance 

operations must be carried out on the power supply unit.

VI) The characteristics of the external switch must 

comply with the EN 61010-1 standard, it must be 

installed near the power supply unit and easily reachable 

by the user.

VII) In order to carry out the connection to the terminal 

board of J2 mains input, make sure that the mains is not 

connected through a the external switch.

Failure to comply with these instructions is dangerous 

for those who use the equipment, apart from the 

possibility to cause equipment breakdowns.

Power-up procedure

Complete the connection correctly before setting at work.

Caution:

 if the power supply unit is powered without 

the provided high-voltage connection between the 

power supply unit and the magnetron, on the outgoing 

Faston connector there is a dangerous voltage; 

DO NOT restore the high-voltage connection before 

discharging the capacitor to earth by means of a 

suitable insulated tool.

Caution:

 connect with a direct cable the earth screw 

of the head with the earth screw of the power supply 

unit. Failure to make this connection may cause 

danger of death!

Activate the external switch to power the equipment; 

FX950T is completely powered by activating the RACK 

POWER UP input with a 24Vdc voltage. The presence of 

the mains is indicated by the green pilot light “POWON” 

on the M330 card. Wait at least 20 seconds for the pre-

heating of the magnetron filament before providing the 

enabling signal.

Activate the output power to the microwave head by 

activating the ENABLING input.

The output of the unit is interrupted when:

1) the ENABLING signal stops

2) the INTERLOCK chain (temporary or permanent 

opening of the NC interlock circuit) is opened

3) the safety thermostat (T=130 °C) placed in the high-

voltage transformer TR2 is opened.

4) the safety thermostat (T=100 °C) placed on the 

Magnetron is opened.

5) one of the fuses blows.

6) the RACK POWER UP signal stops 

Summary of Contents for FX 950 T

Page 1: ...FX 950 T POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE Issue April 2004 ...

Page 2: ...che il Prodotto product name FX950 nome del prodotto FX950 model FX950T modello FX950T Complies with the following norms Soddisfa le seguenti norme EN 61010 1 1994 A2 1996 EN 61010 1993 A2 1995 EN55011 1991 The products listed above comply with the requirements of the Low Voltage Directive 73 23 EEC I Prodotti sopraindicati sono conformi con la Direttiva di Bassa Tensione 73 23 EEC Reggio Emilia A...

Page 3: ...nnection and the utilisation are correct Failure to comply with the instructions implies serious risks for the personnel in charge of the equipment utilisation as well as the possibility to cause equipment breakdowns Electric Specifications Power supply rated 400Vac 50Hz Minimum input voltage 360V Maximum input voltage 440V Input current average value 11 A 400V Rating 4400 VA Efficiency 95 Magnetr...

Page 4: ... V transformer 42AN4500 3 1 5x20 2A T 250V fuse F1 4 2 H V Diode 80D815 5 1 Measure resistance RSZ25002R 6 1 400V 230V autotransformer 42ATC140 001 7 1 5x20 100 mA T 250V fuse F2 8 1 5x20 1A T 250V fuse F3 9 1 Control card 800000330 10 1 Data label List of components 1 2 3 4 5 6 7 Co nnection of the high voltage cable to the magnetron 400 V input Earth screw 8 9 10 ...

Page 5: ...ch must comply with the EN 61010 1 standard it must be installed near the power supply unit and easily reachable by the user VII In order to carry out the connection to the terminal board of J2 mains input make sure that the mains is not connected through a the external switch Failure to comply with these instructions is dangerous for those who use the equipment apart from the possibility to cause...

Page 6: ... case of current leakage due to humidity or dirt along the high voltage path After activating ENABLING if no interlocked conditions are present the ABIL MW led is lit on M330 Within 5 seconds the filament voltage limitation relay is switched the RIDUZ FILAM led is fully lit and the filament voltage drops to an appropriate value NOTES 1 When ENABLING is activated no power is supplied if any of the ...

Page 7: ...pril 2004 Technical note FX 950 T Wiring diagram of FX950T power supply unit with TX030 head Caution it is compulsory to connect the earth screw of the head to the earth screw of the power supply unit failure to do this may cause a death risk ...

Page 8: ...File FX950T_r0eng April 2004 Technical note FX 950 T page 7 of 8 FX 950 T EXTERNAL WIRING DIAGRAM ...

Page 9: ...m How to order Power supply unit for filament FX 950 T Alter reserves the right to make improvements or changes to the product described in the manual at any moment and without prior notice This publication cannot be reproduced without the written consent of Alter All rights are reserved View of the power supply unit Physical characteristics width 250 mm height 235 mm depth 676 mm weight 40 kg ...

Reviews: