ALTER FX 740 T Technical Note Download Page 7

    

FX 740 T  

page    6  

di 7

                                                                                                                                      File: FX740T_r0eng -  Ottobre 2004   -    Manuale per: FX 740 T

    

FX 740 T 

File: FX740T_r0eng -  Ottobre 2004 - Manuale per: FX 740 T                                                                                                                                

         

page     7  

di 7

FAN

TXA20

FX740T

INTERLOCK CHAIN

HIGH VOLTAGE CABLE

25W

AIR cooling

GROUND
SCREW

G

N

D

TRANSFORMER

SSRL1

M4

F

A

S

T

O

N

 

H

E

A

D

 C

O

N

N

.

1

2

3

4

5

6

TR1

AUTOTRAFO

4

0

0

2

3

0

0

M320 BOARD

1

2

3

4

5

6

7

8

9

1

0

1

1

1

2

1

3

1

4

1

5

1

6

1

7

1

8

1

9

2

0

C1

1.3µF

TR2

HIGH VOLTAGE

1

2

4

3

GND

C2

1.3µF

R1

5ohm

 

MAGNETRON 2M130

M1

PHASE1

F1

16A 10x38

F2

16A 10x38

TSW

132°C

F3

1AT 5x20

STOP

START

TSW1

100°C

INTLK1

NC

INTLK2

NC

MOV1

480V

D1

D815

M2

PHASE2

TR3

FILAMENT

F

F

A

0

2

9

0

2

3

0

F

A

+

-

RM1C

60D50

M3

GROUND

Attention: you must connect the ground 

screw of the MW generator to the 

ground screw of the Power supply; failu-

re to comply with this may involve risks 

for the staff.

Wiring diagram FX740T with Generator TXA20

Summary of Contents for FX 740 T

Page 1: ...FX 740 T POWER SUPPLY UNIT FOR 2 KW MAGNETRON TECHNICAL NOTE Issue October 2004...

Page 2: ...il Prodotto product name FX740 nome del prodotto FX740 model FX740T modello FX740T Complies with the following norms Soddisfa le seguenti norme EN 61010 1 1994 A2 1996 EN 61010 1993 A2 1995 EN55011 1...

Page 3: ...ll as the possibility to cause equipment breakdowns Equipment rating Power supply rated 400Vac 50Hz Minimum input voltage 360V Maximum input voltage 440V Input current average value 7 A 400V Rating 29...

Page 4: ...ce Note 1 2 H V Capacitor CR132A2K5 2 1 H V Transformer 42AN3000 8401 3 1 Solid state Relay RERM1C60D50 4 2 Fuseholder for fuse 10x38 mm FUWBBCH2 38 2 Fuse 10x38 mm 16A 500V FU10X38 16A F1 F2 5 1 H V...

Page 5: ...t this operation as well as the reinsertion of the card only when the mains is not connected Failure to comply with these instructions is dangerous for those who use the equipment apart from the possi...

Page 6: ...is supplied if any of the breakdowns mentioned above occurs Do not continue pressing the START key if you do not obtain any result Search the cause of the breakdown Never use a permanent contact switc...

Page 7: ...15 16 17 18 19 20 C1 1 3 F TR2 HIGH VOLTAGE 1 2 4 3 GND C2 1 3 F R1 5ohm M AGNETRON2 M 13 0 M1 PHASE1 F1 16A 10x38 F2 16A 10x38 TSW 132 C F3 1AT 5x20 STOP START TSW1 100 C INTLK1 NC INTLK2 NC MOV1 48...

Page 8: ...05I3001 idw 22 09 03 Prima emissione Botti 286 25 200 25 10 447 10 467 250 420 9 40 Technical Assistance Alter s r l 42100 Reggio Emilia ITALY Tel 39 0522 553 820 fax 39 0522 553 577 Web www altersyst...

Reviews: