- 2 -
DESCRIPTION
With its metal housing, the
SI-MAX
is the essential solution to deter all the intruders thanks to its
very
high power sound!
In alarm, the SI-MAX draws its energy only in the backup battery to prevent damage of the charger of
the control panel.
An automatic limitation of the load current
at 100 mA, even permits several sirens supplied by the
same control panel without risk.
The ISBC function (Intelligent System of Battery Charging) adjusts automatically the charging
voltage
of the battery at 13,8V, the SI-MAX guarantees its full power even when the external power
supply delivers 12V only.
INSTALLATION
The SI-MAX is exclusively provided for an indoor use. It is fixed on
a vertical wall and flat surface greater than the surface of its box,
leaving at least 2 cm on each side. Fix the back plate of the SI-
MAX using 4 screws with cylinder head diameter of 4 to 5 mm (not
supplied).
The removal tamper
is ensured by a screw of 60-70mm of length
and 4 to 5 mm of diameter (not supplied) that should be positioned
as shown against. It must be screwed into the wall until its head
comes into contact with the electronic circuit without forcing.
The opening tamper
is ensured automatically by the slide switch
actuated by the screw cover.
It is imperative to test and verify the proper functioning of the
audible and the tampers after the installation.
It is strongly recommended to check periodically the proper tightening of connections and the status of
the backup battery and replace it if necessary.
WIRING
1
Backup battery
2
Power supply with current limiting battery
3
OV power supply
4
Blocking input 1 intrusion modulation
5
Blocking input 2 discontinuous modulation
6
Tamper circuit
7
Position of the screw for removal tamper
8
Switch for opening tamper
9
Switches of configuration
•
Before wiring the tamper, check that the circuit does not exceed 60VDC/0,1A.
•
Check the correct operation of the tamper after the installation by lifting the cover.
•
If the equipment that drives the SI-MAX is not the same that the one which provides the
power, you have to connect the terminal « 0V » to this equipment to obtain a common
reference.
WARNING ! The SI-MAX will start to trigger only with the internal battery.