background image

E5471 REV03

© 2003 Altec Lansing Professional

1000 W. Wilshire Blvd., Suite 362
Oklahoma City, Oklahoma 73116

Phone: 1-405-848-3108 • Fax:  1-405-848-3217

Web: www.altecpro.com • Email:  [email protected]

P R O F E S S I O N A l

DIMENSIONS ARE IN INCHES.

DIMENSIONS SHOWN IN ( ) PARENTHESES ARE IN MILLIMETERS.

60º

30º

4.98 [126.60]

13.02 [330.64]

9.82 [249.32]

2.99 [76.00]

15.87 [403.00]

16.18 [411.00]

15.51 [393.94]

12.41 [315.14]

MOUNTING DIMENSIONS

SPECIFICATION NOTES

1 The frequency response of the loudspeaker system is measured at a distance of no less than 3 meters to obtain full range data.  The level is
then corrected to be equivalent to a 2.83 V 1 m measurement.  A near field measurement of the loudspeaker system is performed for
frequencies below 500 Hz.  This data is then combined with the full range measurement to give an accurate composite frequency response
curve.

2 The limits of the frequency response are referenced to -3 dB of the systems rated sensitivity.

3 The sensitivity of the loudspeaker system is the log based average SPL taken over the intended bandwidth of operation for the system with a
2.83 V swept sine stimulus.  The data is measured and level corrected in a manner consistent with note 1.

4 The power handling capacity of the loudspeaker system is tested using a full range form of AES Standard 2-1984.  The test stimulus is band
limited (40 Hz – 16 kHz) pink noise with a 6 dB crest factor.  The applied RMS voltage is determined using the minimum impedance of the
system.  The amplifier used to drive the system has a minimum operating headroom of 6 dB referenced to the RMS voltage.

5 The maximum output level of the loudspeaker system is calculated based on the sensitivity and the power handling capabilities of the
system.

6 The coverage angles for the loudspeaker system are taken as the -6 dB points of the directivity response and averaged from 500 Hz – 16 kHz.

7 The minimum impedance of the loudspeaker system is taken over its intended band of operation.

8 The distortion measurements of the loudspeaker system are performed at a distance of 1 m with RMS input voltages corresponding to 1%
and 10% of rated system power handling calculated using minimum system impedance.  The distortion percentages are log based averages
from 300 Hz – 3 kHz.

9 This loudspeaker system is not designed for overhead suspension.

VISIT WWW.ALTECPRO.COM FOR

• Authorized EASE

®

data on Altec Lansing Professional speakers. 

• Specification sheets in .pdf format.  Download page 1 of the specification sheet for your submittals. 

• One paragraph A & E Specifications in .doc format 

Reviews: