Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 67 of 91
P017455 – Rev. C
With Compressor running:
9.13.2
Use a 1-inch paint brush to
dab soapy water on the air
fitting or hose connection to
be tested.
If air bubbles appear at the
connection, this indicates that
air is leaking from the
connection.
If any leaks are detected, take steps to seal them off (as necessary):
•
Tighten the fitting
•
Re-connect the hose end
•
Replace the fitting / hose / component
10. Maintaining Your Dryer
In order to ensure that your P210WLP Series Air Dryer continues to operate efficiently
and reliably, Altec AIR recommends performing preventative maintenance procedures at
the specified six month and annual intervals.
In the event of a high duty cycle application, it may be necessary to perform preventative
maintenance at more frequent intervals, which will be indicated by a compressor total
hour alarm. Refer to
Compressor Total Hour Alarm
(section 10.3 ).
Ensure that this alarm
is reset after each annual maintenance interval to prevent accidental duplicate
maintenance. Refer to
Reset Compressor Total Hours
(section 10.3 ).