ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 59 of 101
P011787 – Rev. R
208 - 230 VAC
for the P1502W, P1502WLP & P1502WHP models
9.4.4
Close Front Panel.
If the incoming voltage measures less than indicated above, it is recommended
that steps be taken at your facility to bring the power to the recommended level of
voltage.
9.5 Measuring Voltages at Solid State Relay
9.5.1
Open Front Panel (section 8.6 ).
9.5.2
Locate the Solid State
Relay inside the dryer at the
top of back wall.
With the Compressor running
:
9.5.3
Use a Voltmeter to measure
across the AC terminals.
Should measure
0 VAC
.
9.5.4
Use a Voltmeter to measure
across the DC terminals.
Should measure:
5 VDC
for the P1500W, P1500WLP & P1500WHP models
12 VDC
for the P1502W, P1502WLP & P1502WHP models
.