ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 58 of 101
P011787 – Rev. R
P1500W, P1500WLP & P1500WHP models
208 - 230 VAC
for the P1502W, P1502WLP & P1502WHP models
9.3.8
Close plastic cover on Control Board over wire #6.
9.3.9
Close Front Panel.
9.4 Measuring Incoming Voltage
9.4.1
Open Front Panel (section
9.4.2
Locate the Incoming
POWER
connector inside
the dryer.
9.4.3
Use a Voltmeter to measure
the voltage (inside dryer):
9.4.3.1
Place the probes
between the Power
Connector and terminal
insulation so that they
touch the metal contacts
for BLACK (BROWN)
wire and WHITE (BLUE) wire.
The voltage should measure:
110 - 125 VAC
for the P1500W, P1500WLP & P1500WHP models
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.
Summary of Contents for PUREGAS P1500W Series
Page 2: ......