Altair EM-202 Owner'S Manual Download Page 7

7

HEADSET CONNECTION

A XLR-4 type connector allows to connect a headset and a microphone to the desk station. The

headset impedance must be 200 

 or higher (up to 2 K

) and the microphone must be dynamic or

electret type. 

For the electret microphone type is necessary to enable the could enable the phantom power

of 9 VDC with a dip-switch placed near the plastic belt clip. In order to obtain more information,
consult the special operation section. 

The microphone preamplifier gain can be configured with a dip-switch placed near the plastic

belt clip in +30 or +40 dB. (In the factory set-up the microphone preamplifier gain is adjusted to +40
dB). In order to obtain more information, consult the special operation section.

The next list shows the XLR pins correspondence:

HEADSET XLR 

PIN 1

0 V (MICROPHONE)

PIN 2

SIGNAL (MICROPHONE)

PIN 3

0 V (HEADPHONES)

PIN 4

SIGNAL (HEADPHONES)

NOTE: 

Headphones can be with a double or single muff. In case of using a double muff

headphone, the two speakers should be wired in parallel mode.

MIC ON/OFF/PUSH TO TALK SWITCH

The ES-200 dual channel beltpack unit is provided with two talk switches, one per

intercom channel. The TALK switch allows to enable/disable the microphone; that way,
we can speak with other units connected to the same intercom channel. If the channel A
microphone isn’t activated (for example), and the channel B microphone is activated, we
will speak with the stations connected to the channel B, but the connected stations to the channel
won’t hear us.

If the microphone is activated, its associated LED will light up, and on the other hand, if it is

disabled, its associated LED will turn off.

The TALK switches have two operation modes. When this switch is pressed quickly, the

microphone changes its state; if it was enabled, being pressed it gets disabled and turns off the
associated LED, and if it was disabled, being pressed it gets enabled and turns on the associated
LED. 

When the TALK switches are pressed and held, the unit will enter in the special function PUSH

TO TALK; this means that the microphone will be enabled until the switch is released.

The unit provides a MIC-KILL (turns off the MIC) system, so that when the mic is enabled it is

possible to muted it by the MIC-KILL function of the master station ALTAIR EF-200. 

BUZZER ON/OFF SWITCH 

This switch enables/disables the buzzer sound when the unit receives a call. When

this switch is pressed, and the buzzer is enabled, it will be disabled, and the LED indicator
will turn off. On the other hand, if the buzzer was disabled, it will be enabled and the LED indicator
will lighten up.

The buzzer sound is different when a call from the channel A is received that when it is

received from the channel B, as well as when a simultaneous call from both channels takes place.

The buzzer also sounds when any switch is pressed, emitting a short hoot.
The unit provides a BUZZER-KILL (turns off the BUZZER) system, so that when the buzzer is

enabled it is possible to muted it by the BUZZER-KILL function of the master station ALTAIR EF-200. 

DUAL CHANNEL BELTPACK EM-202

Summary of Contents for EM-202

Page 1: ...February 09 AUDIO ELECTRONICS DESIGN AUDIO ELECTRONICS DESIGN AUDIO ELECTRONICS DESIGN AUDIO ELECTRONICS DESIGN EQUIPOS EUROPEOS ELECTR NICOS S A L Avda de la Industria 50 28760 TRES CANTOS MADRID SPA...

Page 2: ...SWITCH 7 BUZZER ON OFF SWITCH 7 LINE A AND B LISTEN BALANCE CONTROL 8 CALL SWITCH 8 VOLUME CONTROL 8 AJUSTE DE MONITORIZACI N DE MICR FONO 8 DIP SWITCH DE CONFIGURACI N 8 ACTIVACI N DESACTIVACI N DEL...

Page 3: ...ff Mic Kill operation Buzzer on Call with On Off push switch and indication led lamp Remote Buzzer Off Buzz Kill operation Large Call On Off switch with high visibility light Microphone compressor Lim...

Page 4: ...two different versions depending on the XLR LINE rear connectors of 3 or 5 pin so the rear panel are divided into common elements and elements belonging to each version FRONT PANEL MIC ON OFF PUSH TO...

Page 5: ...the rain and moisture Ensure that no objects or liquids enter it If liquid is spilled into the unit disconnect it from the mains and consult a qualified service technician Do not place the unit close...

Page 6: ...with the increase from the system noise will take place Use high quality cables and minimize its longitude The DC resistance of a low quality cable or very long affects to the power consumption the ch...

Page 7: ...channel B but the connected stations to the channel won t hear us If the microphone is activated its associated LED will light up and on the other hand if it is disabled its associated LED will turn o...

Page 8: ...he switch is pressed and approximately 3 seconds more If a call signal is generated in an external unit beltpacks desk stations master stations etc the LED associated to the CALL switch of the channel...

Page 9: ...SWITCH in OFF the phantom power is disabled and with the position 2 of the set up DIP SWITCH in ON the phantom power is enabled If an electret microphone is used the PHANTOM power must be enabled and...

Page 10: ...NE IMPEDANCE 220 AC 4700 DC NOMINAL LEVEL 10 dBu MAXIMUM LEVEL 3 dBu CALL THRESHOLD 3 VDC REMOTE MIC KILL Power Interruption 100 ms REMOTE BUZZ KILL 100 Hz 800 mVp SIDETONE CANCELLATION Adjustable 0 3...

Page 11: ...icit Any faulty unit must be sent to the dealer or the manufacturer The serial number of the unit must be included for any request to the technical service Equipos Europeos Electr nicos reserves the r...