30
RELAY ACTIVE BY PA OUT KEY
SWITCH
→ PRESET 1.
LED BLINKING
→ The relay
is activated when the PA output
is active
with the PA out
switch.
Factory default.
LED OFF
→ The relay
is not activated when the PA output
is
active with the PA out
switch.
RELAY ACTIVE BY TALK A KEY
SWITCH
→ PRESET 2.
LED BLINKING
→ The relay
is activated when the microphone of the line
A is active with the TALK A
switch.
LED OFF
→ The relay
is not activated when the microphone of the
line A is active with the TALK A
switch.
Factory default.
TALK KEY MODE
SWITCH
→ PRESET 3.
LED BLINKING
→ Push to talk mode, the TALK
switch don't have
latch mode.
LED OFF
→ Latch in short time presses of the switch and push to talk
in long presses of the switch.
Factory default.
CALL/TALK KEYS INVERTED FUNCTION
SWITCH
→ PRESET 4.
LED BLINKING
→ The Call
switch and the talk
switch and indicators
are inverted in function. Call key becomes Talk key and
vice versa.
LED OFF
→ The Call
switch and the talk
switch and indicators,
are working as normal.
Factory default.
CHANGING INVERTED FUNCTION LABELS
.
TALK label. Open the Call lens by pulling it out. Change the included label accordingly.
CALL label. You have to place the included label over the TALK text.
* → The parameters “ONLY EF-204 DIRECT ACCESS“, marked *, can not be set
directly on the EF-202 base station, but can be configured via the control software:
ALTAIR EF-204.
EF-202/EF-204 MASTER STATION - SERIE E-200