background image

 

 

 

12

 

 

E-200 SERIES INTERCOM SYSTEM — EF-200 DUAL CHANNEL MASTER STATION

 

RELAY 

JACK 

¼

” 

 

COMMON 

TIP 

 

NORMALLY CLOSE 

RING 

 

NORMALLY OPEN 

SLEEVE 

 

 

In the factory configuration, the PA output relay is activated with the PA output switch, but the 

multipurpose relay can be configured to be activated upon activating the channel A and/ or B 
microphone or upon activating the remote mute — buzzers signal. In order to obtain more 
information, consult the special operation section.  

 

NOTE:

 The NORMALLY CLOSE terminal is joined with the COMMON terminal when the PA output is 

not activated, and the NORMALLY CLOSE is joined with the COMMON terminal when the PA output 
is activated. 
 

EXTERNAL UNITS CONNECTION 

  

The external units connection to the master station is carried 

through twin-lead shielded cable and XLR-3-31/ XLR-3-32 
connectors. Each master station channel provides two XLR-3-31 
connectors and  a XLR-3-32 connector wired internally in parallel 
mode. 

The next list shows the signal distribution in the pin XLR 

connectors. 

 

 

XLR-3-31/ XLR-3-32 — INTERCOM LINE 

 

PIN 1 

GND

 

 

PIN 2 

+VDC 

 

PIN 3 

SIGNAL

 

 

 

Certain rules have to be followed when installing the cables of an intercom system. This is to 

avoid ground loops and to minimize the power loss and the possible effect of electromagnetic 
fields. 

 

 

Do not connect the XLR pin 1 to the XLR metal housing or to metal wall boxes to avoid ground 

loops. The ground loop could increases notably the system background noise. 

 

 

Do not close the intercom line connection (avoid closed loops). Each intercom line leaves from 

the master station towards the remote stations, but it does not return to the master station. If the 
connection is closed, a ground loop with the increase from the system noise will take place. 

 

 Use high quality cables and minimize its longitude. The DC resistance of a low quality cable or 

very long affects to the power consumption, the channels crosstalk and the system frequency 
response. 

 

 Place the master station the closest possible to the maximum consumption zone; that is to say 

to the zone in which more external units are placed. 
  

The next picture shows the habitual connection of an intercom system formed by four 

beltpacks units (two for each channel) and a master station EF-200. In the section APPLICATION 
EXAMPLES are shown another type of connections. 

 

TIP.
RING.

SLEEVE.

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Summary of Contents for EF-200

Page 1: ...O E L E C T R O N IC SD E S IG N A U D IO E L E C T R O N IC SD E S IG N A U D IO E L E C T R O N IC SD E S IG N EQUIPOS EUROPEOS ELECTR NICOS S A L Avda de la Industria 50 28760 TRES CANTOS MADRID SP...

Page 2: ...ND BLISTE N BALANCECONTROL 18 PROGRAM INPUTLE VE LCONTROL 18 PROGRAM SE NDING TO LINE SA BSWITCHE S 18 PROGRAM TO HE ADPHONE SCONTROL 18 LINE SA AND BLINK SWITCH 18 SL AVECHANNE L SLINK SWITCH 19 E ME...

Page 3: ...nd incorporates new special features as S ystem E xpandability or Battery Operation S ystem E xpandability permits creating a multichannel 4 6 or more channels Intercom S ystem by using more Master S...

Page 4: ...each one will be found in the corresponding section FRONTPANE L CALLS WITCH HE ADS E TCONNE CTOR MICON OF F PUS H TOTALKS WITCH S IDE TONECONTR OL HE ADS E TVOLUMECONTR OL LINEA AND BLIS TE N BALANCEC...

Page 5: ...TCH POWE RS WITCH RE ARPANE L MAINSCONNE CTORAND F US E HOLDE R PA OUTPUTCONNE CTORXLR 3 32 BATTE R YHOLDE R PA OUTPUTR E LAYCONNE CTORJACK PR OGR AM INPUTMIC LINES E LE CTORS WITCH INTE R COM LINECON...

Page 6: ...ALLATION UNPACKING Before leaving the factory each intercom master station has been carefully inspected and tested Unpack and inspect the unit for any damage that may have occurred during shipment If...

Page 7: ...o power difficult situations during a short period of time The use of alkaline batteries is recommended Make sure that the unit power switch is at 0 position turned off In the unit rear panel is place...

Page 8: ...of connection relying on the type of input signal balanced or unbalanced and according to the ground configuration of the equipment floating or ground referenced In the next diagrams we use the follow...

Page 9: ...ded cable BALANCE D INPUT PA OUTPUTCONNE CTION The PA output signal is carried out through a XLR 3 32 male connector The output is balanced with a nominal impedance of 1 00 The next list shows the inp...

Page 10: ...or unbalanced and according to the equipment s ground configuration floating or ground referenced In the next diagrams we use the following symbols S ound destination unit with mains cord without grou...

Page 11: ...ws to carry out a control on an external application every time the PA output is activated connection with unidirectional transmission systems radio stations Lights turn on off motors etc The multipur...

Page 12: ...rules have to be followed when installing the cables of an intercom system This is to avoid ground loops and to minimize the power loss and the possible effect of electromagnetic fields Do not connect...

Page 13: ...master station The volume control of each main station adjusts the headset level of its local intercom lines MAS TE R1 2 S LAVEN 13 4 S LAVEN 2 5 6 S LAVEN 3 7 8 S LAVEN 4 9 10 and the local listen ba...

Page 14: ...ave unit the slave link switch of the master unit is disable the slave unit channel A will be linked with the master unit channel A so that the units connected to the master unit channel A can communi...

Page 15: ...al audio signals in the intercom system The external audio signals could be sent to each channel or to the headphones independently The headset microphone signal is available to drive P A systems R el...

Page 16: ...a simultaneous call from both channels takes place The buzzer also sounds when any switch is pressed emitting a short hoot whose level is higher when it is enabled than when it is disabled The buzzer...

Page 17: ...ches is pressed a call signal is sent to the corresponding intercom channel The call signal makes the LE D associated with the switch start blinking if the buzzer is enabled consult buzzer on off sect...

Page 18: ...al introduced by the program input connector XLR 3 31placed at the rear panel Next to the program input level control is marked the position in which the gain is 0 that is to say the same signal as in...

Page 19: ...f an alkaline battery in a system with a master station unit and four beltpacks is an hour 6 OPTIONS In this section we will explain the different available options for the master station E F 200 unit...

Page 20: ...point for the input transformer TR 2 placed just beside the XLR 3 31program input connector in the rear right corner of the main PCB Before placing the transformer you should remove the two links corr...

Page 21: ...laced at the right part of the main PCB near the front panel looking at the unit from the front panel With the jumper placed the terminal impedance will be connected and with the jumper removed it wil...

Page 22: ...bled and with the position 3 of the DIP S WITCH in ON upwards looking at the unit from the front panel PHANTOM power is enabled If an electret microphone is used the PHANTOM power must be enabled and...

Page 23: ...rner of the main PCBof the unit With the position 6 of the DIP S WITCH in OF F downwards looking at the unit from the front panel the program interruption with the PA MICswitch will be disabled factor...

Page 24: ...LE D E NABLE D With the position 3 of the DIP S WITCH in ON PA KE Y the multipurpose relay will be activated whenever the PA MICswitch will be pressed and with the position 3 of the DIP S WITCH in OF...

Page 25: ...nsformer is sent to the PA output connector The same relay controlled by the MAS TE Rmode detector opens the program input signal in slave mode after crossing the input transformer TR 2 available like...

Page 26: ...26 E 200 SE RIE SINTE RCOM SYSTE M E F 200 DUALCHANNE LMASTE RSTATION Downloaded from www Manualslib com manuals search engine...

Page 27: ...wns as a guide to the qualified technical service helping to repair the unit If a fuse breaks due to a mains transient replace it with the same ratings as described before make sure upon changing the...

Page 28: ...light control and vice versa The intercom line Cintercommunicate the video production and the camera operators The unit installed in the video production is a desk station unit ALTAIRE S 200 connecte...

Page 29: ...Balanced XLR 3 32 OUTPUTIMPE DANCE 100 P A OUTPUT NOMINAL MAXIMUM LE VE L 4 dBu 8 dBu TYPE Balanced XLR 3 31 IMPE DANCE LINE MIC 40 K 2 K PROGRAM INPUT INPUTLE VE L MIC adjustable 15 dBu to 45 dBu LI...

Page 30: ...sent to the dealer or the manufacturer The serial number of the unit must be included for any request to the technical service E quipos E uropeos E lectr nicos reserves the right to modify the prices...

Reviews: