This volume control is used also when adjusting balance or mix settings between level A
and level B for monitoring purposes. See channel select paragraph above for operation.
5.13. CUE LIGHT
GO
INDICATOR
12
GO indicator light shows the user (users) to run the action involved in the CUE.
When the user is ready for the scene he/she can press the STBY key to acknowledge it
to the producer.
The STBY indicator turns steady showing standby.
At this time producer would start the action by pressing the GO key in the master cue
station that would lit all the GO indicators, in green colour.
This indicator does not incorporate a switch as the user can not initiate/finish cues.
6. SPECIAL SETTINGS
The unit can be set to perform some special operating modes to ease daily operations,
adding special functionalities, these are:
6.1. SPEAKER FORCE LISTENING by incoming CALL
Force listening
sets briefly –as long as the remote call is hold- the listen volume of the
unit to maximum setting independent of the normal volume setting of the unit. This mode is
normally used to address a voice message to the surrounding area of the unit, to call attention
or for evacuation purposes. You can select from which channel A, B or both the activation takes
place.
Default setting. DISABLED
6.2. MIC ON by incoming CALL
MIC on by incoming call
sets briefly –as long as the remote call is hold- the mic key
activated independent of the state of the key. This mode is normally used to monitor the activity
of the room where the unit is installed, to hear someone unable to depress the mic key or for
evacuation purposes.
You can select from which channel A, B or both the activation takes place.
Default setting. DISABLED
6.3. MIC & BUZZER off at switch on.
When activated, the mic key and the buzzer would be disabled at switch on. This function
avoids feedbacks and sounds when an unattended unit.
Default setting. DISABLED
6.4. GOOSENECK.
When activated allow operation of a gooseneck boom microphone installed on the
headset connector. See HEADSET connector for details.
Default setting. DISABLED