Via Dante #70787
Floormount tub filler with handshower / robinet de bain au sol avec douchette
alt-aqua.com
INSTALLATION
1.
Prepare the floor
Préparer le plancher
Mark and drill four mounting holes over the floor. (Fig. 1)
Respect your centering.
Marquer et percer quatre trous de montage. (Fig. 1)
Bien centrer la base sur les alimentations.
Minimiz
e
the C-
C
Fig.2
2.
Asymmetrical hose adaptors
Adaptateurs asymétriques
Separate the adaptors from the hoses by unscrewing the nut (4)
(fig.3) while pulling-out at the same time (until the thread is engaged).
Referring to fig.3, install the asymmetrical hose adaptors to the supply-
pipes inlets. Be aware that you can also use 8mm (5/16”) allen keys
to thread the adapters in place.For a
trouble-free installation bring the 2 hoses adapters as close from one
another as possible. The max C-C which can be
accommodated is 23mm.
Séparer les adaptateurs des alimentations flexibles en dévissant leurs
écrous (4) (fig. 3), tout en exerçant une traction (jusqu’à ce que le pas
de vis soit engagé). Se référant à la fig.3, installer les adaptateurs asy
-
métriques sur les arrivées d’eau chaude et froide. Vous pouvez aussi
utiliser une clé Allen 8mm (5/16”) pour fixer les adaptateurs en place
pour une meilleure installation Positionner les deux adaptateurs pour
qu’ils soient aussi proche que possible. Le C-C maxinum qui peut être
accepté est 23mm.
8mm (5/16”)
Fig.1