alpro Weekend-System II Installation Manual Download Page 1

Information on processing regarding the workflow and standard operation procedure (SOP) may be obtained at our website: 

www.alpro-medical.de

, or can be requested by e-mail:

 [email protected]

, or by phone: 

+49 7725 9392-0.

Installation Manual 

(for technicians)

Weekend-System II

Summary of Contents for Weekend-System II

Page 1: ...the workflow and standard operation procedure SOP may be obtained at our website www alpro medical de or can be requested by e mail info alpro medical de or by phone 49 7725 9392 0 Installation Manua...

Page 2: ......

Page 3: ...n 11 3 4 Spare parts 12 II Operating Manual 1 User instructions 13 2 Symbols used on the product information labels and instructions for use 13 3 Target group 14 4 Intended purpose intended use 14 4 1...

Page 4: ...e Biofilm Removing Set BRS is used to remove the biofilm in the water lines of the treat ment unit An application is required for treatment units that have been in operation for more than one year at...

Page 5: ...cted by an expert authorized by ALPRO in accordance with the valid instructions for the drinking water decree In case of interference to the treatment unit the warranty conditions of the manufacturer...

Page 6: ...the treatment unit If necessary the pipes of the treatment unit to the instruments to the tumbler filler and to the bowl rinsing are to be changed in the way that they are connected together to a comm...

Page 7: ...bler filler If the water pressure in the supply line is higher than 6 bar an additional pressure regulator must be installed in front oft he Weekend System II Water entrance Water exit blue compressed...

Page 8: ...n chapter 2 3 and 2 4 f Unscrew the screw in the turning knob of the water stopn and remove the turning knob Remember the position of the turning knob Remove the cover g Fit the pipes for water and co...

Page 9: ...rmationen siehe Handbuch ALPRO MEDICAL GMBH Mooswiesenstr 9 D 78112 St Georgen Schwarzwald Tel 0 77 25 93 92 0 Fax 0 77 25 93 92 91 E mail alpro alpro medical de Internet www alpro medical de Endkontr...

Page 10: ...0130 80770840 80700057 80700013 80770170 80770840 80710047 80710048 80700017 80710046 80770092 80710047 8551 80700057 80710047 80770107 80700062 80700062 80770121 Explosionszeichnung Weekend System II...

Page 11: ...hrottle valve Filter Check valve Water supply Air supply Pressure control Pressure valve Check valve Filler neck Strainer Level indicator Pressure tank Water exit Hand piece Tumbler bowl rinsing 3 3 C...

Page 12: ...supply assembly REF 8252 Pressure regulator assembly REF 8253 Socket check valve assembly REF 8254 Assembly group check valve REF 8255 Assembly riser tube tank REF 8551 Spare part water filter Note Wh...

Page 13: ...or use Safety related information Special features the observance of which is necessary for the perfect function of the device Use before date of expiry YYYY MM Batch number XXXXXX six digit Symbol fo...

Page 14: ...ersonnel It must not be operated by the patient The Weekend System II may only be operated within the pressure areas indicated Air pressure in inlet line 3 8 bar air pressure in the tank 2 bar water i...

Page 15: ...rformance of the devices The basic cleaning of the waterways with the Biofilm Removing Set BRS must not be carried out with the Weekend System II 6 Basic cleaning with BRS before installation Exclusiv...

Page 16: ...1 Standby mode during the week Weekend System II is switched off Tap water flows freely Tank is without pressure the tank pressure valve blocks the air path 7 2 Injection of BILPRON Last working day...

Page 17: ...shown on the right The toggle for compressed air has always to be set on 0 pressure release after having finished the injection of BILPRON The rotary switch for water stop should always be closed in...

Page 18: ...the water stop ball valve on I 2 Then pressurize the tank Set the toggle switch of the pressure valve on I c Adjust all instruments to maximum flow and remove them 8 3 Timing of use Before work breaks...

Page 19: ...r to flood the main lines as soon as pos sible Operate the tumbler filler several times 2 Then continue with the multifunctional syringes and finally rinse the lines with the smallest flow 3 All instr...

Page 20: ...other for approx 3 minutes Record the decontamination with BILPRON in the device record book Procedure f Depressurize the tank Set the toggle switch of the pressure valve on O Keep the water stop valv...

Page 21: ...ary Tank cap 1 2 times a year the thread on the tank cap and on the tank nozzle including the O rings must be cleaned and coated with a little Vaseline by trained specialist personnel Cleaning Please...

Page 22: ...e tank has been overfilled of the Weekend System II No water flows Perhaps the water stop is still closed Open the valve see Chapter 7 1 Too little water flows Possibly the filters of the treatment un...

Page 23: ...nents of the unit and chemicals must be disposed of in accordance with the legal regulations applicable in the country Questions about proper disposal can be answered by your dental trader Packaging c...

Page 24: ...ite www alpro medical de If you have any questions please do not hesitate to contact us at www alpro medical de or by phone 49 7725 9392 0 You are also welcome to contact our sales representatives by...