background image

Waterproof Keypad

AS626S

Read all instructions before starting installation

To set new master code 

TAKE TIME TO ALLOW EACH BUTTON INPUT / LED TO REGISTER

Enter

 

H H 

1 2 3 4 

H H

 

The keypad enters programming mode, 

the Red LED flashes

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

0-0-0# 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

new 4-8 digit code 

This is the new master code, record the 

number and keep it safe

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Re-enter

  the new master code 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 #

Enter

 

To exit programming mode

To set a new master code of 112233

Enter

 

H H 

master code 

H H

 2 000# 112233# 112233# #

To set a new user code

Enter

 

H H 

master code 

H H

 

The keypad enters programming mode, 

the Red LED flashes

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

address of new user code  i.e. 001 (001-200 accepted)

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

new 4-8 digit user code 

This is the new user code, record the 

number and keep it safe

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Re-enter

  the new 4-8 digit user code  The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

The new code is added, to add new codes 

continue from second step, changing the 

address each time. When finished enter an 

additional # to exit programming mode.

Re-Enter

  2 to set the next code or # to EXIT

To set a new user code of 6626 in address 1

Enter

 

H H master code H H  2 001# 6626# 6626# #

To set a new user code of 6626 in address 1 & 7788 in address 2

Enter

 

H H 

master code

 

H H

  2 001# 6626# 6626# 2 002# 7788# 7788# #

To remove an individual user code - 

Only the user code addresses are 

removable, the master code may be changed but not removed

Enter

  

H H 

master code 

H H

 

The keypad enters programming mode, 

the Red LED flashes

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

address of user code to

be removed 

Example 001 (001-200 accepted)

Enter 

The red LED illuminates for 2 seconds and 

then flashes (Address accepted)

Enter

 

address of user code to

be removed 

Example 001 (001-200 accepted)

Enter

 

The red LED illuminates for 2 seconds and 

then flashes the code is removed

Enter

 

Exit programming mode 

To remove all user codes

Enter

 

H H 

master code 

H H

 

The keypad enters programming mode, 

the red LED flashes

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

master code

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes 40 sec. All user code addresses 

are removed

Enter

 

For exit programming

To set lock open time

Enter

 

H H 

master code 

H H

 

The keypad enters programming mode, 

the Red LED flashes

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

door open time 

(01-99) Ex. 05 = 5 seconds

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

For exit programming

To set the door open time to 10 seconds

Enter

  

H H 

master code 

H H

 1 10 # #

To set output relay to latching mode (On-Off)

Enter

  

H H 

master code 

H H

 

The keypad enters programming mode, 

the Red LED flashes

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

00

Enter

 

The Red LED illuminates for 2 seconds and 

then flashes

Enter

 

The relay is set to latching mode

TO PROGRAM THE RELAY FOR A TIMED FUNCTIONING PLEASE PERFORM 

PROCEDURE 5.

To set Normally Open 

Enter

 

H H 

master code

H H 

 

The keypad enters programming mode, 

the Red LED flashes

Enter

 

 The red LED illuminates for 2 seconds and 

then flashes

Enter

 

Enter

 

 The Red LED illuminates for 2 seconds then 

flashes

Enter

 

 Exit the programming mode

To set Normally Closed

Enter

 

H H 

master code 

H H 

 

The keypad enters programming mode, 

the Red LED flashes

Enter

 

 The red LED illuminates for 2 seconds and 

then flashes

Enter

 

Enter

 

 The Red LED illuminates for 2 seconds then 

flashes

Enter

 

 Exit the programming mode

OPERATING THE KEYPAD

Enter

  

user code # 

The relay operates and Green LED 

illuminates

If three incorrect attempts are made to enter a user code, the keypad will lock 

out for thirty seconds

DATA RESET

There are two basic models out in the field. Before attempting Data Reset identify 

the model concerned. Dependent on model select correct reset instructions.
In the event that programming administration is lost, or errors have been made 

in the programming, it is possible to set the keypad master back to the factory 

default:

Version 1

Power off to keypad - wait 5 seconds - reapply power to Keypad

When power reapplied - if Red LED stays on for 1 second = Version 1

If the unit has been fitted with, this process will destroy the anti-tamper plugs

Remove anit-tamper plugs and the keypad from the wall
Press the reset button on the rear of keypad

The red LED illuminates for 2 seconds and then flashes

Enter

1234#

 

The red LED illuminates for 2 seconds and a 

continuous tone is heard

Press the reset button on the rear of keypad 

Enter #

 

The red LED illuminates for 2 seconds and 

then flashes

Enter

#

 

The relay is set to open the door for 5 

seconds

Master code 

1-2-3-4

User code 

5-6-7-8-9-0

Version 2

Power off to keypad - wait 5 seconds - reapply power to Keypad

When power reapplied - if Red LED stays on for 3 seconds = Version 2
Power up the unit

  During the first 3 seconds the Red LED is ON

Enter 

**

1234#  

Green LED will appear then turn to Red LED

The unit will sound 3 times and the data will 

be restored as follows

Master code 

1-2-3-4

User code 

5-6-7-8-9-0

 

Please erase this code at address 200

Door open time 

5 seconds

Warranty

This product is guaranteed for a period of 

5 years

 against defects in manufacture, 

workmanship or materials provided that all electrical and mechanical installation 

requirements are adhered to as per this instruction sheet. All third party and 

consequential claims are expressly excluded from this warranty.

1

6

3

4

5

7

8

2

PROGRAMMING THE KEYPAD CONTINUED..

Reviews: