Monitored Electric Strike
AL2000
Read all instructions before starting installation
As shown in Figure 1, there
should be 1mm gap between
the door latch and the front
face of strike keeper to prevent
the door from exerting back
pressure on the keeper when
the door is closed.
When door is closed, make sure there is no back
pressure on the keeper strike.
When the above installation is completed,
connect the wiring, secure the strike with
appropriate screws and check operation.
Note:
The control circuit for the door strike is protected against reverse polarity
connection.
PACK CONTENTS
DOOR LATCH POSITION
INSTALL ON METAL FRAME
MOUNTING STEPS OF STRIKE
Power Input
12 vDC - current 220 mA
24 vDC - current 110 mA
Wire output
Red (+)
Black (-)
LSS (Lock Status
Sensor)
Black (Common)
Yellow (NO-PTO),
NC-PTL)
Green (NC-PTO),
(NO-PTL)
DSS (Door Status
Sensor)
Black (Common)
Blue (NO)
Orange (NC)
ATS (Anti-Tamper
Sensor)
Black (Common)
Red (no)
White (NC)
Sensor Output
LSS Sensor Output 3A,
125 vAC, 2A, 30 vDC
DSS Sensor Output
3A, 125 vAC, 2A,
30 vDC
Anti-tamper Sensor
Output 5A, 125 vAC,
3A, 250 vAC
POWER INPUT 12VDC OR 24VDC SUPPLY
1
2
x4
x2
x1
x2
x1
x1
x2