Monitored Electric Strike

AL2000

Read all instructions before starting installation

As shown in Figure 1, there 
should be 1mm gap between 
the door latch and the front 
face of strike keeper to prevent 
the door from exerting back 
pressure on the keeper when 
the door is closed.

When door is closed, make sure there is no back 

pressure on the keeper strike.

When the above installation is completed, 

connect the wiring, secure the strike with 

appropriate screws and check operation.

Note: 

The control circuit for the door strike is protected against reverse polarity 

connection.

PACK CONTENTS

DOOR LATCH POSITION

INSTALL ON METAL FRAME

MOUNTING STEPS OF STRIKE

Power Input

12 vDC - current 220 mA

24 vDC - current 110 mA

Wire output

Red (+)

Black (-)

LSS (Lock Status 

Sensor)

Black (Common)

Yellow (NO-PTO), 

NC-PTL)

Green (NC-PTO), 

(NO-PTL)

DSS (Door Status 

Sensor)

Black (Common)

Blue (NO)

Orange (NC)

ATS (Anti-Tamper 

Sensor)

Black (Common)

Red (no)

White (NC)

Sensor Output

LSS Sensor Output 3A, 

125 vAC, 2A, 30 vDC

DSS Sensor Output 

3A, 125 vAC, 2A, 

30 vDC 

Anti-tamper Sensor 

Output 5A, 125 vAC, 

3A, 250 vAC

POWER INPUT 12VDC OR 24VDC SUPPLY

1

2

x4

x2

x1

x2

x1

x1

x2