![Alpine TME-M770 Service Manual Download Page 34](http://html1.mh-extra.com/html/alpine/tme-m770/tme-m770_service-manual_2908016034.webp)
TME-M770
E
B
C
MODE
Q100
4.4
5
5.2
Q101
4
4.6
6.5
Q102
4
4.6
6.5
Q103
4
4.6
6.5
Q104
4
4.6
6.5
Q105
5.8
5.2
4.9
Q106
7.2
6.5
3.3
Q107
7.2
6.5
3.3
Q108
7.2
6.5
3.3
Q109
7.2
6.5
3.3
Q110
4.3
4.9
8.8
Q111
2.6
3.3
8.8
Q112
2.7
3.3
8.8
Q113
2.7
3.3
8.8
Q114
2.7
3.3
8.8
Q116
0
0
4.6
Q117
3.9
4.5
8.8
Q118
3.8
4.4
8.8
Q121
2.3/0
0/14
0/0
MUTE(OFF/ON)
Q123
0/0
0/5
0.28/0 MUTE(OFF/ON)
Q124
0/0
0/4.1
5/0
F.BRAKE(OFF/ON)
Q125
0/0
0/4.1
5/0
REVERSE(OFF/ON)
Q126
5/5
5/3.8
0/5
H.BRAKE(OFF/ON)
Q127
5/5
5/3.8
0/5
P.BRAKE(OFF/ON)
Q134
2.4
1.8
0
Q135
2.4
1.8
0
Q136
2.4
1.8
0
Q137
0/0
5/0
0/9
MUTE(OFF/ON)
Q139
0/0
5/0
0/5
NTSC/PAL
Q140
0
3.2
0.9
Q141
2.3/0
0/13.3
0/0
MUTE(OFF/ON)
Q143
5
5
0
Q144
0
0
5
1
2
3
4
5
Q138
NC
0/13.3 13.4/13.4
0/9
0/0
MUTE(OFF/ON)
Q145
0
4.5
0
0
0
Q146
NC
5/0
5/5
5/0
0/0
NAVI/AUX
1
2
3
4
5
6
Q129
0/0
0/0
0/0
0/12.6
NC
0/12.6 MUTE(OFF/ON)
[Measuring Conditions]
1.Power Supply Voltage
: DC14V
2.Measuring Meter
: Digital Multi Meter
3.Measuring Point Reference
: Between GND
4.Measuring Condition
: connect Monitor Unit
MODE
MODE
- 41 -