![Alpine CDE-9821R Service Manual Download Page 19](http://html.mh-extra.com/html/alpine/cde-9821r/cde-9821r_service-manual_2907570019.webp)
CDM-9823R/CDM-9823RR/CDE-9822RB/
CDE-9821R/CDE-9821RM
Pin No.
B
E
C
Q001
9.1
8.5
14.3
Q002
9.1
8.5
14.3
Q003
5.8
5.2
14.3
Q004
0 / 8.4
8.5
8.4 / 0.3
FM/MW,LW
Q005
12.7
12
14.2
Q006
14
13.3
14.2
Q010
0
0
12
Q011
4.9
0
0
Q015
3.1/0.24
0
0
LW/FM,MW
Q201
0
0
5
#1,$1 Q261
0
0
0
#1,$1 Q262
0
0
0
Q263
0
0
0
Q264
0
0
0
Q301
0
0
4.1
%1 Q401
0.6
0
0.1
#1,$1 Q601
5
5
0
Q607
0
0
4.7
%1 Q608
0
0
4.95
Q664
4.95
4.95
0
Q701
3.8
4.5
2.1
CD
Q702
0
0
2.5
CD
Q751
14.4
14.4
7.2 / 0
CD / RADIO
Q803
13.5
14.3
14.2
Q804
4.9
0
0
Q805
9.3
8.6
14.3
Q807
9.5
8.9
14.4
Q863
4.94
0
0
NOTE : #1 : For CDM-9823R Model Only, $1 : For CDM-9823RR Model Only,
%1 : For CDE-9822RB Model Only, Others : Common.
[Measuring Conditions]
1.Power Supply Voltage
: DC14.4V
2.Measuring Meter
: Digital Multi Meter
3.Measuring Point Reference
: Between GND
4.Measuring Condition
: FM : 98.1MHz
AM : 999KHz
CD : at playing Disc
FM mode expect noted.
* All the data was measured in
- 22 -
TO SCHEMATIC
TO CONTENTS