![Alpine CDA-9847R Service Manual Download Page 21](http://html1.mh-extra.com/html/alpine/cda-9847r/cda-9847r_service-manual_2907398021.webp)
CDA-9847R/CDE-9845RB/CDE-9845RR/
CDE-9843R/CDE-9843RM
No.
Voltage
Condition
No.
Voltage
Condition
No.
Voltage
Condition
1
4.25
4
0
7
4.28
2
4.24
5
4.28
8
8.58
3
4.25
6
4.28
No.
Voltage
Condition
No.
Voltage
Condition
No.
Voltage
Condition
1
0
10
8.85
19
7.54
2
0
11
1.4
20
14.14
3
7.45
12
1.4
21
7.48
4
4.91/0
POWER IC ON/OFF
13
0
22
4.19/0
MUTE OFF/ON
5
7.46
14
1.4
23
7.42
6
14.12
15
1.4
24
0
7
7.54
16
1.38
25
0
8
0
17
7.55
9
7.54
18
0
No.
Voltage
Condition
No.
Voltage
Condition
No.
Voltage
Condition
1
0
4
0
7
4.88
2
4.88
5
0
8
4.85
3
4.88
6
4.88
No.
Voltage
Condition
No.
Voltage
Condition
No.
Voltage
Condition
1
PULSE
23
PULSE
45
PULSE
2
PULSE
24
PULSE
46
PULSE
3
PULSE
25
PULSE
47
PULSE
4
PULSE
26
PULSE
48
PULSE
5
PULSE
27
PULSE
49
PULSE
6
PULSE
28
PULSE
50
PULSE
7
PULSE
29
PULSE
51
PULSE
8
PULSE
30
PULSE
52
PULSE
9
PULSE
31
PULSE
53
PULSE
10
PULSE
32
PULSE
54
PULSE
11
PULSE
33
PULSE
55
PULSE
12
PULSE
34
PULSE
56
4.8/4.8
POWER ON/OFF
13
PULSE
35
PULSE
57
4.9/4.9
POWER ON/OFF
14
PULSE
36
PULSE
58
3.1/3.1
POWER ON/OFF
15
PULSE
37
PULSE
59
1.5/1.5
POWER ON/OFF
16
PULSE
38
PULSE
60
0/0
POWER ON/OFF
17
PULSE
39
PULSE
61
3.7/3.7
POWER ON/OFF
18
PULSE
40
PULSE
62
PULSE
19
PULSE
41
PULSE
63
PULSE
20
PULSE
42
PULSE
64
PULSE
21
PULSE
43
PULSE
22
PULSE
44
PULSE
NOTE : #1 : For CDA-9847R Model Only, &1 : For CDE-9843R Model Only, #2 : For CDE-9843RM Model Only,
Others : Common.
IC307
IC401 (&1,#2)
IC350 (#1)
IC302 (#1)
- 21 -