507330-01B

Page 30 of 33

Issue 1809

BG801UH1

10CE20 

Performance (Less Filter)

External 

Static 

Pressure

 

in. w

.c.

Air V

olume / W

atts at V

arious Blower Speeds

Bottom Return 

Air

, Side Return 

Air with Optional Return 

Air Base, Return 

Air from Both Sides or Return 

Air from Bottom and One Side.

Single Side Return 

Air - 

Air volumes in 

bold 

require field fabricated transition 

to accommodate 20 x 25 x 1 in. air filter in order to maintain proper air velocity

.

High

Medium - 

High

Medium

Medium - 

Low

Low

High

Medium - 

High

Medium

Medium - 

Low

Low

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

0.00

2230

635

1945

430

1715

295

1555

230

1470

185

2315

645

1990

415

1780

300

1610

230

1510

200

0.10

2180

655

1905

445

1690

305

1510

240

1340

175

2260

655

1945

425

1740

315

1550

240

1400

185

0.20

2135

680

1865

465

1630

330

1470

260

1280

190

2210

680

1895

460

1680

335

1510

255

1350

200

0.30

2090

695

1830

480

1595

345

1440

275

1235

200

2165

700

1850

465

1650

355

1455

275

1285

210

0.40

2050

715

1785

495

1550

360

1385

285

1175

210

2135

715

1830

485

1585

365

1395

285

1230

225

0.50

2025

730

1740

520

1500

375

1340

300

1130

225

2095

730

1770

500

1535

385

1365

300

1175

235

0.60

2010

750

1710

535

1470

390

1305

320

1080

240

2055

755

1725

515

1495

400

1305

315

1135

250

0.70

1965

755

1670

555

1420

410

1255

330

1015

255

2000

765

1675

535

1465

410

1255

325

1080

265

0.80

1905

785

1635

560

1380

425

1215

350

975

270

1965

785

1640

555

1400

425

1210

345

1025

275

BG801UH090CE20 

Performance (Less Filter)

External 

Static 

Pressure

 

in. w

.c.

Air V

olume / W

atts at V

arious Blower Speeds

Bottom Return 

Air

, Side Return 

Air with Optional Return 

Air Base, Return 

Air from Both Sides or Return 

Air from Bottom and One Side.

Single Side Return 

Air - 

Air volumes in 

bold 

require field fabricated transition 

to accommodate 20 x 25 x 1 in. air filter in order to maintain proper air velocity

.

High

Medium - 

High

Medium

Medium - 

Low

Low

High

Medium - 

High

Medium

Medium - 

Low

Low

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

cfm

watts

0.00

2255

640

1940

420

1750

310

1580

230

1485

185

2290

655

1980

425

1775

310

1605

235

1495

195

0.10

2200

655

1910

440

1705

315

1535

240

1385

190

2250

675

1945

445

1730

320

1555

245

1400

190

0.20

2150

675

1865

450

1655

640

1490

260

1340

205

2210

695

1885

465

1680

340

1510

265

1350

205

0.30

2125

695

1835

475

1635

355

1450

275

1285

215

2165

715

1850

475

1645

355

1470

275

1285

215

0.40

2090

715

1800

495

1585

370

1405

285

1235

230

2135

720

1810

490

1595

370

1410

290

1225

230

0.50

2060

735

1760

510

1545

385

1370

305

1200

245

2070

735

1765

515

1545

390

1370

305

1180

245

0.60

2020

750

1725

525

1515

405

1320

320

1145

255

2030

760

1715

530

1495

405

1325

320

1140

255

0.70

1980

765

1680

540

1465

420

1265

330

1105

270

1990

775

1685

540

1450

425

1265

330

1095

270

0.80

1935

785

1635

560

1420

435

1225

350

1055

285

1950

795

1645

560

1415

435

1225

345

1040

285

Summary of Contents for Blueridge BG801UHE

Page 1: ...th Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Installation and service must be performed by a licensed professional in...

Page 2: ...5 mm air filter 2 Single side return air with optional RAB Return Air Base 3 Bottom return air 4 Return air from both sides 5 Bottom and one side return air 2 Flue outlet may be horizontal but furnace...

Page 3: ...vestibule area In order to ensure proper unit operation combustion and ventilation air supply must be provided according to the current National Fuel Gas Code Vent installations must be consistent wi...

Page 4: ...control the furnace The use of fixed jumpers that will provide continuous heating is prohibited d The input rate and temperature rise must be set per the furnace rating plate e Supply and Return air...

Page 5: ...Gas Code ANSI Z223 1 This reprinted material is not the complete and official position of the ANSI on the referenced subject which is represented only by the standard in its entirety All gas fired ap...

Page 6: ...space Each opening must be at least 100 square inches 64516 mm2 One opening shall be within 12 inches 305 mm of the top of the enclosure and one opening within 12 inches 305 mm of the bottom See Figu...

Page 7: ...he furnace on its front or its back Do not connect the return air ducts to the back of the furnace Doing so will adversely affect the operation of the safety control devices which could result in pers...

Page 8: ...urnace is equipped with a removable bottom panel to facilitate installation Markings are provided on both sides of the furnace cabinet for installations that require side return air Cut the furnace ca...

Page 9: ...erall Maximum 584 23 3 4 19 1 22 7 16 570 Overall Maximum SIDE RETURN AIR OPENINGS Either Side 5 5 8 143 1 Minimum 11 279 2 Maximum 14 356 683 26 7 8 7 1 4 184 FURNACE FRONT AIR FLOW IF BASE IS USED W...

Page 10: ...l injury and or property damage could result WARNING The inner blower panel must be securely in place when the blower and burners are operating Gas fumes which could contain carbon monoxide can be dra...

Page 11: ...h the flue transition pointed down in the 6 o clock position The combustion air inducer may be rotated clockwise or counterclockwise by 90 to allow for top or side vent discharge in all applications W...

Page 12: ...h inducer motor Disconnect pressure switch hose from barbed fitting on the pressure switch assembly Remove pressure switch assembly 1 screw and cut wire tie to free pressure switch wires Reinstall pre...

Page 13: ...sphyxiation hazard The exhaust vent for this furnace must be securely connected to the furnace flue transition at all times WARNING Figure 22 Vent Connection Use self drilling sheet metal screws or a...

Page 14: ...s A type B1 vent or masonry chimney liner shall terminate above the roof surface with a listed cap or a listed roof assembly according to the terms of their respective listings and the vent manufactur...

Page 15: ...1 2 feet 46 m for each inch 25 mm of common vent diameter 10 The vent pipe should be as short as possible with the least number of elbows and angles required to complete the job Route the vent connect...

Page 16: ...15 136 20 226 22 339 5 22 65 30 130 39 219 49 330 10 29 59 40 121 51 206 64 315 15 35 53 48 112 61 195 76 301 20 0 0 97 0 202 0 349 0 540 2 10 75 14 149 18 250 20 377 5 21 71 29 143 38 242 47 367 10...

Page 17: ...220 15 1 21 50 33 89 47 142 64 220 2 22 53 35 96 49 153 66 235 3 24 55 36 102 51 163 68 248 20 1 21 54 33 99 46 157 62 246 2 22 57 34 105 48 167 64 259 3 23 60 35 110 50 176 66 271 30 1 20 62 31 113 4...

Page 18: ...urn on the appliance that is being inspected Adjust the thermostat so that the appliance operates continuously 5 After the burners have operated for 5 minutes test for leaks of flue gases at the draft...

Page 19: ...111 85 2750 77 87 2200 62 30 1900 53 80 1680 47 57 1520 43 04 1400 39 64 1300 36 81 1220 34 55 1150 32 56 2 1 2 63 5 2 469 67 713 6300 178 39 4350 123 17 3520 99 67 3000 84 95 2650 75 04 2400 67 96 22...

Page 20: ...sources of ignition to check for gas leaks CAUTION The furnace must be isolated by closing its individual manual shut off valve and disconnecting from the gas supply system the during any pressure te...

Page 21: ...ergized in the heating mode when the combustion air inducer is operating Any humidifier rated up to one amp can be connected to this terminal with the neutral leg of the circuit being connected to one...

Page 22: ...507330 01B Page 22 of 33 Issue 1809 Figure 31 Wiring Diagram...

Page 23: ...depress and hold button longer than 5 seconds Table 8 Diagnostic Codes for 03 Control 03 Integrated Control LED Codes Red LED Flash Code2 Diagnostic Codes Status of Furnace LED Off No power to control...

Page 24: ...switch CAUTION Figure 32 Integrated Control Automatic Hot Surface Ignition System Terminal Designations 120 HUM Humidifier 120 VAC LINE Input 120 VAC XFMR Transformer 120 VAC CIRC Indoor Blower 120 V...

Page 25: ...per access panel 10 Turn on all electrical power to the unit 11 Set the thermostat to desired setting NOTE When unit is initially started steps 1 through 11 may need to be repeated to purge air from g...

Page 26: ...measurements have been taken Manifold Pressure Measurement 1 Remove the threaded plug from the outlet side of the gas valve and install a field provided barbed fitting Connect to a manometer to measur...

Page 27: ...s not adjustable The heat fan off delay amount of time that the blower operates after the heat demand has been satisfied may be adjusted by changing the jumper position across the five pins on the int...

Page 28: ...or insulate 5 Refer to blower speed selection chart on unit wiring diagram for desired heating or cooling speed See Blower performance data 6 Connect selected speed tap at integrated control speed te...

Page 29: ...30 920 190 865 180 625 135 0 70 1190 350 1000 235 855 205 790 190 540 140 0 80 1160 365 925 245 790 205 735 200 445 145 BG801UH090BE16 Performance Less Filter External Static Pressure in w c Air Volum...

Page 30: ...5 410 1255 325 1080 265 0 80 1905 785 1635 560 1380 425 1215 350 975 270 1965 785 1640 555 1400 425 1210 345 1025 275 BG801UH090CE20 Performance Less Filter External Static Pressure in w c Air Volume...

Page 31: ...y Replacement filters must be rated for high velocity airflow Table 1 lists recommended filter sizes Flue and Chimney 1 Check flue pipe chimney and all connections for tightness and to make sure there...

Page 32: ...installer or equivalent service agency or gas supplier Cabinet Parts Upper access panel Blower panel Top cap Control Panel Parts Transformer Integrated control Door interlock switch Circuit breaker Bl...

Page 33: ...height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than...

Reviews: