After  40  seconds  the Led of   GSM   
starts  fast  blinking.  Then  if  GSM  is 
registered and full service, the Led is 
blinking slow.

In another case see in Bluegate ISDN Brave 
Configuration in Diagnostics ->GSM Modules 
Status what is the matter. 

Try to call

Now it is time to save your setting into device. 

Summary of Contents for Blue Gate ISDN BRI Brave

Page 1: ...al rezistors Open the box and set switches for terminal rezistors There are 4 switches for connecting 100 Ohm terminal rezistors Switches 1 2 are used for TE mode switches 3 4 are used for NT mode Default setting is TE off NT on Synchro mode Router Synchro No Yes Start TE mode Find out PIN code at various mobile phone and remember it When you run Configuration SW you can type it in configuration d...

Page 2: ...s possibility of GSM interferences 2 Main 230 V for power supply of BlueGate ISDN Brave 3 Quality of GSM signal at the installation place Connect device to main 230V INPUT 100 240V 0 7A 50 60Hz OUTPUT 5V 3A DC Plug Dimension 5 5mm x 2 5mm Correctly connect USB cable and ISDN lines Set initial parameters of Bluegate ISDN Brave Configuration SW on the PC to work device correctly Start Bluegate ISDN ...

Page 3: ...u want to use network connection set all parameters Blue Gate Brave1 You can assign the name of your equipment Choose the proper Dial tone Set parameters for TE mode In case of Synchro mode no need to adjust anything no matter Set at least the following parameters Set parameters for NT mode according to the connected PBX ...

Page 4: ...nd maximum length of DTMF digits Type PIN code if there is one Include the GSM modules GSM1 and GSM2 to the appropriate groups Enter the number where incoming calls are directed All calls are routed to the extension entered in this table in order if the parameter Waiting for DISA is 0 or number of called digits is less then Minimal extension length Max count of this extension is 5 ...

Page 5: ... which will be sent 0 means that length of called number is unknown and end of dial is recognized after timeout defined in Wait for dialing This parameter can make the call arrangement faster In router mode if any item is not in Routing table all calls are routed from the PBX to the PSTN and vice versa You can ADD the routing item One line will be added into routing table You can EDIT default rout...

Page 6: ...blinking Then if GSM is registered and full service the Led is blinking slow In another case see in Bluegate ISDN Brave Configuration in Diagnostics GSM Modules Status what is the matter Try to call Now it is time to save your setting into device ...

Reviews: