TUBING AND COMMISSIONING 

 

• 

Connect the tubes to the thread inputs marked with IN and OUT  

 The other thread input must be closed by the screw plug:

 

 

 

 

• 

Now fill the Eisball with a funnel through the upper fillport. The optimal filling height is 

10mm below the upper fillport opening: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use the screw tool. 

10 mm 

We only recommend clear coolants 
from our own production (CKC or 
Eiswasser Crystal - no UV!) or pure 
distilled or osmosis filtered water. 

After commissioning the pump for the 
first time, the water level drops. 
Therefore, liquid should be refilled 
during use. 

Summary of Contents for EISBALL

Page 1: ...EISBALL...

Page 2: ...Eisball Alphacool International GmbH 1...

Page 3: ...FETY INSTRUCTIONS 15 MOUNTING MATERIAL 16 TECHNICAL DETAILS 17 INSTALLATION 20 INSTALLATION OF THE PUMP 20 MOUNTING IN CASE 20 CONNECTING LEDS 23 PLACING LED RING 23 CONNECTING ARGB CONTROLLER 23 TUBI...

Page 4: ...Eisball Alphacool International GmbH 3 40 40 LED 43 LED 43 RGB 43 44...

Page 5: ...en sind haben rein informativen Charakter Wir bernehmen keine Gew hr f r die Richtigkeit dieser Angaben Hinsichtlich der Art und des Umfangs der Lieferung sind allein die in Bestellung und Auftragsbes...

Page 6: ...chsbeh lter 1x Pumpenmontage Tool 1x Verschlussschrauben Tool 1x Montageblech 1x Klettmatte 1x Halterung f r L ftermontage 4x Vibrationsd mpfer 1x Verschlussschraube 4x M4x5 Schrauben 4x M3x5 Schraube...

Page 7: ...Eisball Alphacool International GmbH 6 3 Gewindeeing nge TECHNISCHE DETAILS Ma e in mm Maximales Wasservolumen ca 700 ml...

Page 8: ...Eisball Alphacool International GmbH 7 Pumpenkompatibilit t Die Maximalh he der eingebauten Pumpe darf 50 mm nicht berschreiten Montageblech Der Eisball ist mit der VPP655 und der VPP755 kompatibel...

Page 9: ...Eisball Alphacool International GmbH 8 L fterhalterung...

Page 10: ...dargestellt MONTAGE IM GEH USE Bevor Sie den Eisball im Geh use montieren stellen Sie manuell die gew nschte Pumpenst rke ein F r genauere Informationen berpr fen Sie die Anleitung Ihrer Pumpe Anschl...

Page 11: ...r Klettmatte Nutzen Sie die beiliegenden M3x5 Schrauben um das Montageblech am Geh use zu montieren Des Weiteren besteht die M glichkeit die beiliegende Klettmatte zur Befestigung am Geh use zu nutzen...

Page 12: ...Eisball Alphacool International GmbH 11 Vibrationsd mpfer L fterhalterung M4x5 Schrauben 2 Montage mit L fterhalterung 1 2 M3x5 Schrauben...

Page 13: ...l International GmbH 12 BELEUCHTUNG INSTALLIEREN LED RING AUFSETZEN Schieben Sie den LED Ring von oben auf den Ausgleichsbeh lter ANSCHLUSS ARGB CONTROLLER Schlie en Sie den aRGB Controller folgenderm...

Page 14: ...all mithilfe eines Trichters durch den oberen Fillport Die optimale F llh he betr gt 10 mm unter der oberen Fillport ffnung Nutzen Sie das Verschlussschrauben Tool 10 mm Wir empfehlen ausschlie lich k...

Page 15: ...Eisball Alphacool International GmbH 14...

Page 16: ...gues circulars announcements or price lists have a purely informative character We do not undertake warranty for the correctness of these data As to the kind and the range of delivery the data contain...

Page 17: ...uded Art No 13324 1x reservoir 1x pump mounting tool 1x screw tool 1x mounting plate 1x Velcro mat 1x fan bracket 4x vibration damper 1x sealing plug 4x M4x5 screws 4x M3x5 screws 1x LED ring 1x mini...

Page 18: ...Eisball Alphacool International GmbH 17 TECHNICAL DETAILS Dimensions in mm Maximum capacity approx 700 ml 3 threads...

Page 19: ...Eisball Alphacool International GmbH 18 Pump compatibility The maximum height of the installed pump must not exceed 50 mm Mounting plate The Eisball is compatible with the VPP655 and the VPP755...

Page 20: ...Eisball Alphacool International GmbH 19 Fan bracket...

Page 21: ...all the pump in the reservoir as shown MOUNTING IN CASE Before mounting the Eisball in the case manually set the desired rotational speed For more detailed information check your pump manual Then moun...

Page 22: ...lcro mat lower Velcro mat Use the included M3x5 screws to mount the mounting plate to the case It is also possible to use the included Velcro mat to attach it to the case Attach the upper Velcro mat t...

Page 23: ...Eisball Alphacool International GmbH 22 vibration damper fan bracket M4x5 screws M3x5 screws 2 Mounting with fan bracket 1 2...

Page 24: ...Eisball Alphacool International GmbH 23 CONNECTING LEDS PLACING LED RING Place the LED ring on the reservoir from above CONNECTING ARGB CONTROLLER Connect the aRGB controller as follows power supply...

Page 25: ...he Eisball with a funnel through the upper fillport The optimal filling height is 10mm below the upper fillport opening Use the screw tool 10 mm We only recommend clear coolants from our own productio...

Page 26: ...de la justesse de ces informations Concernant le type et volume de la livraison seulement les informations contenues dans la commande et la confirmation de la commande sont d cisives 2 En cas de d fa...

Page 27: ...servoir 1x outil pour le montage de la pompe 1x outil de bouchon 1x plaque de montage 1x bande en velcro 1x support de ventilateur 4x amortisseurs de vibrations 1x bouchon 4x vis M4x5 4x vis M3x5 1x b...

Page 28: ...Eisball Alphacool International GmbH 27 FICHE TECHNIQUE Dimensions en mm Capacit maximale approx 700 ml 3 filetages...

Page 29: ...Eisball Alphacool International GmbH 28 Compatibilit pompe La hauteur maximale de la pompe install e ne doit pas d passer 50 mm Plaque de montage L Eisball est compatible avec la VPP655 et la VPP755...

Page 30: ...Eisball Alphacool International GmbH 29 Support de fixation du ventilateur...

Page 31: ...nte FIXATION EN BOITIER Avant de fixation du Eisball dans le bo tier r glez manuellement la vitesse de rotation de la pompe souhait e Pour de plus amples informations consultez le manuel de votre pomp...

Page 32: ...ieure de la bande velcro Utilisez les vis M3x5 ci jointes pour monter la plaque de montage sur le bo tier Il est galement possible d utiliser la bande velcro fournie pour la fixation au bo tier Fixez...

Page 33: ...Eisball Alphacool International GmbH 32 amortisseurs de vibrations support de ventilateur vis M4x5 vis M3x5 2 Montage avec support de ventilateur 1 2...

Page 34: ...isball Alphacool International GmbH 33 INSTALLATION DU ECLAIRAGE PLACER BAGUE LED La bague LED est plac e sur le r servoir CONNEXION CONTROLEUR ARGB Connectez le contr leur aRGB comme suit alimentatio...

Page 35: ...c un entonnoir par l ouverture sur le c t La hauteur de remplissage optimale est de 10 mm en dessous de l ouverture sup rieure Utilisez l outil de bouchon 10 mm Nous conseillons uniquement l utilisati...

Page 36: ...RNATIONAL GMBH 1 2 2 13 1 14 3 ALPHACOOL 4 ALPHACOOL INTERNATIONAL GMBH ALPHACOOL INTERNATIONAL GMBH 5 ALPHACOOL INTERNATIONAL GMBH ALPHACOOL INTERNATIONAL GMBH ALPHACOOL INTERNATIONAL GMBH 6 ALPHACOO...

Page 37: ...Eisball Alphacool International GmbH 36 EISBALL 15362 EISBALL 13324 1x 1x 1x 1x 1x 1x 4x 1x 4x M4x5 4x M3x5 1x LED 1x aRGB 1x aRGB EISBALL 13324 1x Eis VPP 755 1x O...

Page 38: ...Eisball Alphacool International GmbH 37 mm 700 ml 3...

Page 39: ...Eisball Alphacool International GmbH 38 50 mm Eisball VPP655 VPP755...

Page 40: ...Eisball Alphacool International GmbH 39...

Page 41: ...Eisball Alphacool International GmbH 40 1x O 1x 1x 1x M4x5 Eisball Eisball 1 2 1 1...

Page 42: ...Eisball Alphacool International GmbH 41 M3x5 M3 5 2...

Page 43: ...Eisball Alphacool International GmbH 42 M4x5 M3x5 2 1 2...

Page 44: ...Eisball Alphacool International GmbH 43 LED LED LED RGB aRGB...

Page 45: ...Eisball Alphacool International GmbH 44 IN OUT Eisball 10 mm 10 mm CKC Eiswasser Crystal UV...

Page 46: ......

Page 47: ......

Page 48: ......

Page 49: ...r Str 1 38122 Braunschweig Support 49 0 531 28874 0 Fax 49 0 531 28874 22 E Mail info alphacool com General Manager Fabian Noelte WEEE Reg Nr DE 544444 Trade Register Amtsgericht Braunschweig HRB 2023...

Reviews: