2.1 General Requirements
2.1.1 General Section
#
Feature
Detailed Description
2.1.1.1 Antenna
Type
Two UFL antenna connectors
s
2.1.1.2 Operating
Voltage
3.3VDC +/- 10%
2.1.14 Form
Factor
and
Interface
Mini-PCI type III A form factor
2.2 Requirements of Reliability,
Maintainability and Quality
#
Feature
Detailed Description
2.2.1 MTBF
Mean Time Between Failure > 30,000 hours
2.22
Maintainability
There is no scheduled preventive maintenance required
2.2.3
Quality
The product quality is followed-up by Alpha Networks
factory quality control system
2.3 Environmental Requirements
#
Feature
Detailed Description
2.3.1
Operating
Temperature
Conditions
The product is capable of continuous reliable operation when operating
in ambient temperature of 0
℃
to +40
℃
.
2.3.2
Non-Operating
Temperature
Conditions
Neither subassemblies is damaged nor the operational performance is
degraded when restored to the operating temperature after exposing to
storage temperature in the range of –20
℃
to +75
℃
.
2.3.3
Operating
Humidity
conditions
The product is capable of continuous reliable operation when subjected
to relative humidity in the range of 10% and 90% non-condensing.
2.34
Non-Operating
Humidity
Conditions
The product is not damaged nor the performance is degraded after
exposure to relative humidity ranging from 5% to 95% non-condensing