7
Notes:
1. All wiring is #22AWG unless shown otherwise.
2. When using a PINHOLE type camera, instead of the standard S.T.R.
™
modular type camera, see the special
camera installation and connection instructions found on page 8, and do not power as shown above.
3. DO NOT CONNECT MORE THAN 10 MONITORS PER RISER/LINE.
4. Observe all local and national electrical and building codes.
5. All terminals connections shown may not be in the order that they appear on the equipment.
TYPICAL WIRING DIAGRAM FOR DUAL ENTRANCE SYSTEM
WITH S.T.R.
™
STYLE CAMERA AND ONE (1) VIDEO RISER
(NO VIDEO DISTRIBUTORS)
Note: For systems with more
than two (2) entrances, or other
configurations, please consult the
factory or your nearest Alpha
Communications® distributor.
VH30CAK or
Note: When using the
model VCU6-2 power
supply instead of the
VCU6 power supply,
the 'KAM' terminals
will be shown as
'CAM' instead.