Alpha Vannus VC 1 Instruction Manual Download Page 2

Warning

Installation and maintenance work shall only be performed by qualified persons, familiar 

with local code and regulation, and experienced with this type of appliance.

All field wiring must be installed in accordance with the national wiring regulation.

Ensure that the rated voltage of the unit corresponds to that of the name plate before 

commencing wiring work according to the wiring diagram.

The unit must be GROUNDED to prevent possible hazard due to insulation failure.

The earth wire is approximately 60mm longer than safety wire. This is to ensure at the 

event whereby the suspension system fails, the (L) and (N) wire will break leaving the 

fan remain earthed to prevent electrocution.

Tighten the blade firmly using a screw driver.

Blades that are detached from the unit during operation will cause serious injuries and 

property damages.

This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliances.

Confirm that the power supply has been switched OFF before installing or servicing the 

unit. Ensure that the blade is fully static before doing any maintenance work.

Safety Precaution

1. Safety Precaution ................................................................................. 1 - 2
2. Parts & Accessories .............................................................................. 3
3. Installation Instruction ........................................................................... 4 - 7
4. Power Supply Connection .................................................................... 7 - 8
5. Circuit Diagram ..................................................................................... 8
6. Transmitter Programming ..................................................................... 9
7. Transmitter Function & Assembly ......................................................... 10
8.  Maintenance ........................................................................................ 11
9. Technical Specifications ....................................................................... 11 - 12
10. Customer Service Centre ................................................................... 12

Summary of Contents for Vannus VC 1

Page 1: ...VC 1 INSTRUCTION MANUAL ...

Page 2: ...river Blades that are detached from the unit during operation will cause serious injuries and property damages This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Chi...

Page 3: ...locations which may cause injury hazards Avoid from being in contact with these places Before turning off the power supply set the remote controller s ON OFF switch to the OFF position If this is not done the unit s fans will start turning automatically when power resumes posing a hazard to service personnel or the user Do not operate any heating apparatus too close to the ceiling fan unit or use ...

Page 4: ... Downrod Coupling Cover Motor Assembly Blade Transmitter Kit Transmitter Holder x 1 AAA AAA Battery x 2 Blade Screw Washer x 7 3 3 Assembly Kit 3 FAN ON FAN OFF 1 2 3 4 5 6 LIGHT ON F R LIGHT OFF 1H 2H 4H 8H ...

Page 5: ...anopy Cover and Coupling Cover through the Downrod Step 2 Fix the Rubber assemble to the Downrod with Bolt Washer Nut and tighten them firmly then insert the Clevis Pin IMPORTANT Clevis pin MUST be insert to prevent nut from loosening Canopy Coupling Cover Bolt Washer Nut Clevis Pin ...

Page 6: ...om the Downrod Place the Rubber Pulley onto the ceiling hook and fix back the Bolt Clevis Nut and Washer Tie the Safety Wire across the hook as shown and firmly screw the Safety Wire onto the Downrod Rubber Pulley Clevis Pin Nut Washer Bolt Safety Wire Safety Wire ...

Page 7: ...n Yellow Green Yellow E Step 7 Connect the Connectors from Fan and Receiver Connect the wires from the receiver to House s Supply Wire Tighten Earth Wire back to Downrod and connect to House Supply Earth Terminal Step 8 Install the Blades on Motor with Screw Washer Install Switch Housing onto fan by twisting in Switch Housing ...

Page 8: ...7 Below shows a complete installation diagram ...

Page 9: ...8 ANT1 W N Pink Red Grey Neutral Blue Power Supply Live Brown Earth Green Yellow Earth Green Yellow Blue Brown Green Yellow MAIN PCB L E V U 220V 240V 50Hz 220V 240V 50Hz DC Motor ...

Page 10: ...d into transmitter b Turn on the power supply wall switch to the fan c Within 30 sec press and hold the FAN ON button for 3 sec Once the receiver has detected the frequency transmitter will Beep Beep twice Programming process is completed and fan is ready to use If the fan is not responding to the transmitter repeat Step 1b Press and hold for 3 sec Transmitter Learning Process FAN ON FAN OFF 1 2 3...

Page 11: ... fan fan will operate as the last setting Function of Forward Reverse Fan must be turned on and rotating Press F R button and fan will slow down and then change direction approx 15 sec When the fan is slowing down to change direction the Fan Speed function is disabled until direction has been changed Forward Fan rotates anti clockwise blowing the air downwards creating the wind chill effect Suitab...

Page 12: ...VC 1 Max 185 Max 35W Motor Wattage Fan Width No of Blades 52 3 220V 240V 50Hz 11 ...

Page 13: ...lan Molek 3 10 Taman Molek 81100 Johor Bahru Tel 07 353 4833 4933 Fax 07 355 4233 Melaka 19 19 1 19 2 Jalan KSB 11 Taman Kota Syahbandar 75200 Melaka Tel 06 292 6292 6293 Fax 06 292 6296 Perak 16 Jalan Tasek Timur Taman Tasek Indra 31400 Ipoh Perak Tel 05 545 2282 547 2282 Fax 05 547 6282 Penang 28 Jalan Icon City Icon City 14000 Bukit Mentajam Penang Tel 04 506 2366 2066 2566 Fax 04 506 2966 Paha...

Reviews: