FlexPoint

 FPR1207-F Quick Start Guide

FTTx UPS System for ONTs  — 

Model FPR1207-F

The power supply cord is used as the main disconnect device. Verify the socket/outlet is located/
installed near the equipment and is easily accessible.

CAUTION!

Alpha Technologies 3767 Alpha Way Bellingham, WA 98226 USA Tel: +1 360 647 2360 Fax: +1 360 671 4936 www.alpha.com
Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC, V5J 5M4 CANADA Tel: +1 604 436 5900 Fax: +1 604 436 1233
Due to continuing product improvements, Alpha reserves the right to change specifi cations without notice.
Copyright © 2011 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies. 010-344-B0-001 Rev. A (01/2011)

010-344-B0-001 Rev. A 01/2011

Specifi cations

Input

AC Input Voltage:

120Vac/240Vac

Input Frequency: 

50/60Hz

Output

Operational Output Power:

7W (ONT load)

Output Voltage:

12Vdc Nominal (Battery voltage upon loss of AC)

Connection:

F-type coaxial

Battery

Type:

7.2Ah AGM

Recharge Time

18 Hours to 90%

Battery Backup

Provides approximately 20 Hours of backup at 3.5W*

Provides approximately 12 Hours of backup at 7W*

*Based on new, fully-charged battery

Physical

Housing Size (in/mm):

8.75W x 7.75H x 3.0D/222W x 197H x 76D

Weight (lb./kg):

1.3/0.59

Battery 7.2Ah (lb./kg):

5.7/2.6

Visual Status Indicators

Green LED: 

AC mode

Green LED Flashing:

Battery mode

Red LED:

Failed self test

Red LED fl ashing:

Battery missing/Low battery

Audible Status Indicators

Loss of Input Power:

Single, one second beep

Low Battery:

Single 0.5 second beep every 15 seconds at 25% SOC

Replace Battery:

Double beep  every 15 minutes

Push Buttons

Silence Alarm:

Suppresses the audible alarm for 24 hours

Battery Emergency Use:

Accesses reserve battery capacity

Agency Compliance

Safety (US):

NRTL certifi ed to UL/CSA 60950-1 Ed. 2 (ITE) (Pollution Degree 2, Overvoltage 
Category II), LPS Output, SELV

Safety (other):

IEC 60950-1:2005 + National Deviations.  (Pollution Degree 2,  Overvoltage 
Category II), LPS Output, SELV

Safety (EU):

CE, EN 60950-1:2006
Evaluated for use with an IT power system

EMC (US):

FCC part 15 subpart b, Class B

EMC (EU):

CE, EN 55022:2006 (CISPER 22) (Emissions) Class B, EN 55024:1998 +A1 +A2 
(Immunity), EN 61000-3-2:2006 (Harmonics), EN 61000-3-3 (Fluctuations and Flicker)
CE, RoHS compliant

Environment

Storage Temperature:

-20°C to +50°C (-4°F to +122°F)

Operating Temperature:

0°C to 40°C (32°F to 104°F)

Note: Operating temperatures based

 

on AX-LONGBAT-7

Humidity:

5% to 95%

Elevation Operation (max.):

0 to 10,000ft (0 to 3,000m)  — derate 2°C per 1,000ft (305m) above 6,000ft (1830m)

Elevation Storage (max.):

50,000ft (15,000m)

Battery Storage:

-20°C to +40°C (-4°F to +104°F)

(six months max. storage duration at 25°C / 77°F without a recharge)

Warranty

FlexPoint FPR1207-F:

3-year, repair or replace

Battery:

Contact Alpha Technologies for model-specifi c warranty coverage

Fig. 1, System block diagram

Review the drawings and illustrations contained in this guide 

before proceeding. For 

additional details on installation and 

operation, visit www.alpha.com and download a copy of the 
FlexPoint

TM

 FPR1207-F/FPR1207-F Technical Manual. 

The FPR1207-F is an optical network terminal (ONT) power 
supply that provides 7W of primary and standby power 
at 12Vdc. The FPR1207-F converts customer supplied 
120Vac/240Vac, 50/60Hz outlet voltage to a 12Vdc output. 
Status reporting is provided locally via audible and visual 
alarms. Standby power is provided by one 7.2Ah battery 
installed in the FPR1207-F. Upon loss of AC power the 
FPR1207-F supports the load until the battery reaches 25% 
remaining usable capacity. At that point, the FPR1207-F 
enters sleep mode preserving capacity for emergency 
calls. Pressing the Emergency Use button accesses the 
remaining capacity.

ONT

FlexPoint

TM

 

FPR1207-F

Up to 6' (1.8m)

FPR1207-F RG6 or 

similar home coax 

cabling. Up to 50'

 (15m)

Network 

Area

Customer

Area

1.  Unpack and inspect the FPR1207-F. 

2.  The unit is designed for use in a sheltered environment protected from rain and snow. Its operating 

temperature range is 0°C to 40°C / 32°F to 104°F (ambient). Install the unit near an AC outlet.

3.  Remove battery compartment door by pressing tab and opening door. Remove the door and set aside until 

the installation process is complete.

4.  Determine the necessary cable length to provide appropriate service loops between the FPR1207-F, the 

ONT, and the outlet. Plug the line cord into the receptacle on the back of the FPR1207-F. Do not plug the 
FPR1207-F into an AC outlet until the last step of the installation procedure.

5.  Mount the FPR1207-F to the wall with #12 fasteners or equivalent, using the keyholes for easy mounting. 

For applications (with 7.2Ah battery only) with higher seismic requirements, use the round holes in the back 
of the unit for direct fastening to a stud or other structural feature.

6.  Connect Coax cable to F-type connector.

Installing and Connecting the FPR1207-F