Alpha CD25X/28X

The clock allows you to set the times at which the boiler will operate to provide central heating. It does not affect the supply 
of domestic hot water, which is always available whatever the setting of the clock.

1.  TO SET THE TIME

Turn the outer dial clockwise to set the clock hands to 
the correct time.
(Ensure the time indicator corresponds with the correct 
time on the 24hr dial as shown in Fig. 2,
e.g. 3.00pm = 15 not 3).

NOTE: Do not rotate the dial anti-clockwise

2.  TO SET THE ON/OFF PERIODS

Select the ON times by pushing the tappets out.
Select the OFF times by pushing the tappets in.
Fig. 2 shows the clock set as follows:-
 

ON 

3.00pm 

to  10.00pm (15 - 22)

 

OFF 

10.00pm  to  5.00am (22 - 5)

 

ON 

5.00am 

to  8.00am (5 - 8)

 

OFF 

8.00am 

to  3.00pm (8 - 15)

3.  MANUAL SWITCH

The clock has a manual On/Off switch which operates as follows:-
 

Mid position 

Heating On/Off as set by the tappets

 

Position 

I

 (right) 

Heating On continuously

 

Position 0 (left) 

Heating Off continuously

Fig. 2

9  GAS SAFETY REGULATIONS

10  CLOCK (if fitted)

Current Gas Safety (Installation and Use) Regulations:-
It is the law that all gas appliances are installed and serviced by a competent person, i.e. Gas Safe registered personnel. 
Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure 
compliance with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations.
The Benchmark Checklist must be fully completed by the installer on installation of the boiler. The Benchmark Checklist is 
shown in Section 12 of the Installation and Servicing instructions. All Gas Safe registered installers carry a Gas Safe ID card 
and have a registration number. Both should be recorded in the Checklist. You can check your installer is Gas Safe registered 
by calling Gas Safe on 0800 4085500.

Summary of Contents for Alpha CD25X

Page 1: ...Natural Gas only Leave these instructions with the User Range of Wall Mounted Fan Assisted Room Sealed Gas Fired High Efficiency Condensing Combination Boilers 0051 Nepicar House London Road Wrotham H...

Page 2: ...ower heating temperatures are required turn the thermostat ant clockwise If higher temperatures are required turn the thermostat clockwise 2 DOMESTIC HOT WATER THERMOSTAT This thermostat controls the...

Page 3: ...2 Additional frost protection to pipework external to the boiler may be required Refer to Fig 1 for boiler controls 1 Ensure the following a Electrical supply to the boiler is off b All heating contr...

Page 4: ...fan stops after 50 seconds The pump will continue to run for three minutes d When a hot tap is opened the boiler automatically senses a flow of water The pump will start the fan will operate and the...

Page 5: ...ntact your plumbing merchant or installer for advice when considering purchasing such items 5 CLEANING Use only a damp cloth and mild detergent to clean the boiler outer casing Do not use abrasive cle...

Page 6: ...s Mid position Heating On Off as set by the tappets Position I right Heating On continuously Position 0 left Heating Off continuously Fig 2 9 GAS SAFETY REGULATIONS 10 CLOCK if fitted Current Gas Safe...

Page 7: ...the boiler is on If so Check that all controls are calling for heat i e room thermostat clock If so Check that the gas supply is on If the light continues to come on after resetting Contact the Alpha...

Page 8: ...been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement Alpha Therm Limited 2011 Alpha Therm Limited NepicarHouse LondonRoad Wro...

Reviews: