CD18/24/30/32 LPG Supplement

3

BOILER LOCATION

Installation pipes, cylinders and pressure regulators should be fitted in accordance with BS 5482:1. Bulk tank installation must
comply with the requirements of the Home Office code of practice for the storage of liquefied petroleum gas at fixed installations.

The boiler 

must not 

be installed in a room or internal space below ground level, e.g. in a basement or cellar, except where at

least one side is open to ground level.

4

INSTALLATION

In addition to the regulations and requirements stated in the Installation and Servicing instructions, the boiler 

must be 

installed

in accordance with BS 5482:1 - The Installation of Propane Burning Appliances in Permanent Dwellings.

5

COMMISSIONING

The boiler has been tested and factory set for use with Propane gas and it should only be necessary to ensure the correct gas
supply pressure of 37 mbar is available.

2.3

GAS SUPPLY

The Alpha CD18S boiler requires a gas rate of 1.3 kg/h (2.8 lb/h) or 2.5 litres/h of liquid gas.

The Alpha CD24 boiler requires a gas rate of 1.9 kg/h (4.1 lb/h) or 3.6 litres/h of liquid gas.

The Alpha CD30S boiler requires a gas rate of 2.2 kg/h (4.7 lb/h) or 4.2 litres/h of liquid gas.

The Alpha CD32 boiler requires a gas rate of 2.53 kg/h (5.6 lb/h) or 4.9 litres/h of liquid gas.

The supply pipes must be capable of delivering this quantity of gas in addition to the demand from any other appliances in the
house. The boilers require at least a 22 mm gas supply pipe, except for the CD18S which requires a 15 mm gas supply pipe.

The complete installation must be tested for gas soundness against leakage.

The local Propane gas supplier should be consulted, at the installation planning stage, in order to establish the availability of
an adequate supply of gas.

37.0

14.8

13.2

2.9

15.4

3.4

Alpha CD32C

MAX.

36.2

123 500

32.6

111 300

32.0

109 200

6.07

2.4

1.4

49.4

MIN.

7.3

24 900

6.6

22 500

6.6

22 500

0.4

0.16

0.28

9.9

Domestic Hot Water

Heat Input (H

s

)

kW

(Gross)

Btu/h

Heat Input (H

i

)

kW

(Net)

Btu/h

Output to Water (H

s

)

kW

(modulating)

Btu/h

Differential Burner

mbar

Pressure

in wg

Gas Supply Pressure (LPG)

mbar

in wg

Gas Rate (LPG)

m³/h

ft³/h

Flow Rate at 35°C Rise

L/min

gal/min

Specific Flow Rate (D) at 30°C Rise

L/min

(Flow rate @ 30K to EN625)

gal/min

Room sealed
chamber
panel fitted

Alpha CD30S and CD32C

MAX.

31.1

106 100

28.0

95 550

29.8

101 700

28.0

95 500

4.48

1.8

1.2

42.4

MIN.

7.3

24 900

6.6

22 500

7.0

23 900

6.5

22 200

0.4

0.16

0.28

9.9

Room sealed
chamber panel
fitted

Central Heating

Heat Input (H

s

)

kW

(Gross)

Btu/h

Heat Input (H

i

)

kW

(Net)

Btu/h

Heat Output (H

condensing)

kW

(50°C/30°C)

Btu/h

Heat Output (H

i

 non-condensing)kW

(80°C/60°C)

Btu/h

Differential Burner

mbar

Pressure

in wg

Gas Supply Pressure (LPG)

mbar

in wg

Gas Rate (LPG)

m³/h

ft³/h

37.0

14.8

Reviews: