7. ELECTRICAL SUPPLY
The boiler requires a 230/240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of plug is used.
To connect a plug:-
The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the terminals
in your plug. In this case proceed as follows:-
The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter E, or by the
earth symbol
, or coloured green or green and yellow.
The blue wire must be connected to the terminal which is marked with either the letter N or coloured black.
The brown wire must be connected to the terminal which is marked with the letter L or coloured red.
THE APPLIANCE MUST BE EARTHED.
7
GAS SAFETY REGULATIONS
If you experience a problem of no heating, try to solve the problem by following the simple checks below before calling out a
service engineer.
If applicable, pull the controls panel cover forward and down to gain access to the controls.
8
FAULT FINDING FOR THE USER
Current Gas Safety (Installation and Use) Regulations:-
It is the law that all gas appliances are installed and serviced by a competent person, i.e. CORGI registered personnel. Failure
to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance
with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations.
The Benchmark Checklist must be fully completed by the installer on installation and commissioning of the boiler. The
Benchmark Checklist is shown in Section 12, page 34, of the Installation and Servicing instructions. All CORGI registered
installers carry a CORGI ID card and have a registration number. Both should be recorded in your central heating Checklist.
You can check your installer is CORGI registered by calling CORGI on 01256 372300.
Leaflet compiled and designed by Publications 2000 - Tel: (01670) 356211
11/08/D229
Part No. 1.022776
These instructions have been carefully prepared but we reserve the right to
alter the specification at any time in the interest of product improvement.
© Alpha Therm Limited 2008.
Alpha Therm Limited.
Nepicar House, London Road, Wrotham Heath,
Sevenoaks, Kent TN15 7RS
Tel: 0870 3001964
email: [email protected]
website: www.alpha-innovation.co.uk
A
B
C
- Check that the electrical supply to the boiler is on. If so
- Check that all controls are calling for heat, i.e. room thermostat, clock. If so
- Check that the gas supply is on. If the light continues to come on after resetting
Ring the
Alpha Helpline Service
Tel: 0870 3001964
You will be asked
the Serial No. of your
boiler when you ring.
The Serial No. is located
on the underside of
the boiler.
If any of these lights are on or flashing,
rotate the selector switch to RESET (position 3)
See C
Turn to
maximum
Two channel clock
(if fitted)
Turn selector to
(position 2)
ON
If this light is not on
See A
This light should illuminate
If not - See B
0
1
2
3
1
2
3
4
5
6
7
8
9
RESET
ON
OFF
FROST
A
D
B
C
SELECTOR
THERMOSTAT
CD18R