Alpha Alpha 500E (LPG) Instructions Download Page 2

2

500E LPG Supplement

1

INTRODUCTION

This supplement is for the LPG model of the boiler; it must be read in conjunction with the 'Installation and Servicing
Instructions' supplied with the boiler and provides the extra information which is particular to LPG.

The Alpha 500E boiler is a wall mounted, fan assisted room-sealed combination boiler with unvented hot water storage. Heat
output is controlled by a modulating gas valve.

The boiler, providing both central heating and domestic hot water at mains pressure, is designed for use with a fully pumped,
sealed and pressurised heating system using only PROPANE gas.

2

TECHNICAL DATA

2.1

PERFORMANCE - PROPANE GAS

MAX.

34.5

117 700

28.0

95 550

35.0

14.0

1.3

47.1

MIN.

13.2

45 000

10.4

35 500

5.8

2.32

0.51

18.0

MAX.

34.5

117 700

28.0

95 550

35.0

14.0

1.3

47.1

20.0

4.4

MIN.

13.2

45 000

10.4

35 500

5.8

2.32

0.51

18.0

1.0

0.22

Room sealed chamber
panel fitted

Room sealed chamber
panel fitted

Central Heating

Heat Input

kW

Btu/h

Heat Output (modulating)

kW

Btu/h

Burner Pressure

mbar

Settings

in wg

Gas Supply Pressure (LPG)

mbar

in wg

Gas Rate

m³/h

ft³/h

CH Water Temp. (Approx. max.) °C

°F

37.0

14.8

82

180

37.0

14.8

65

149

12.0 minutes

5.0 minutes

Domestic Hot Water

Heat Input

kW

(Gross)

Btu/h

Output to Water (modulating)

kW

Btu/h

Burner Pressure

mbar

Settings

in wg

Gas Supply Pressure (LPG)

mbar

in wg

Gas Rate

m³/h

ft³/h

Flow Rate

L/min

G.P.M.

Outlet Water Temp. (Approx. max.) °C

°F

Time to raise water storage 50°C

Reheat time for 70% of storage

2.2

GAS SUPPLY

The boiler requires a gas rate of 2.4 kg/h (5.3 lb/h) or 4.7 litres/h of liquid gas.

The supply pipes must be capable of delivering this quantity of gas in addition to the demand from any other appliances in the
house. The boiler requires at least a 22 mm gas supply pipe.

The complete installation must be tested for gas soundness against leakage.

The local Propane gas supplier should be consulted, at the installation planning stage, in order to establish the availability of an
adequate supply of gas.

Installation pipes, cylinders and pressure regulators should be fitted in accordance with BS 5482:1. Bulk tank installation must
comply with the requirements of the Home Office code of practice for the storage of liquefied petroleum gas at fixed
installations.

3

BOILER LOCATION

The boiler must not be installed in a room or internal space below ground level, e.g. in a basement or cellar, except where at
least one side is open to ground level.

Summary of Contents for Alpha 500E (LPG)

Page 1: ... these instructions with the User Alpha 500E LPG Wall Mounted Fan Assisted Room Sealed Gas Fired Combination Boiler with Unvented Hot Water Storage Goldsel Road Swanley Kent BR8 8EX Fax 01322 615017 For Technical help or for Service call ALPHA HELPLINE Tel 01322 669443 0051 ...

Page 2: ...max C F 37 0 14 8 82 180 37 0 14 8 65 149 12 0 minutes 5 0 minutes Domestic Hot Water Heat Input kW Gross Btu h Output to Water modulating kW Btu h Burner Pressure mbar Settings in wg Gas Supply Pressure LPG mbar in wg Gas Rate m h ft h Flow Rate L min G P M Outlet Water Temp Approx max C F Time to raise water storage 50 C Reheat time for 70 of storage 2 2 GAS SUPPLY The boiler requires a gas rate...

Page 3: ...G The boiler has been tested and factory set for use with Propane gas and it should only be necessary to ensure the correct gas supply pressure of 37 mbar is available 6 PARTS LIST The following parts are special to Propane boilers For other Short List Spare Parts refer to the Installation and Servicing instructions supplied with the boiler Components Main burner injectors Gas valve spring Convers...

Page 4: ...ecification at any time in the interest of product improvement Alpha Therm Limited 1996 06 96 D32 Alpha Therm Limited Goldsel Road Swanley Kent BR8 8EX Tel 01322 669443 Fax 01322 615017 DETAILS OF BOILER INSTALLATION Date of Installation Name of Installer Address Postcode Telephone No Boiler Serial Number LPG see data label on inside of left hand case panel ...