Twin Pipe Flue Systems
4
INSTALLATION
4.1
INSTALL THE BOILER
Mount the boiler on the wall and connect the pipework as described in the Installation and Servicing instructions supplied with
the boiler.
4.2
CONVERT THE BOILER (see Fig. 5)
Modify the top of the boiler to enable a 2-pipe flue system to be connected using conversion kit 1000368 as follows:-
1.
Place the flue duct adaptor in position onto the boiler flue adaptor and secure with the clamp and seal.
2.
Select the required position of the air duct adaptor and remove the three screws securing the cover plate.
3.
Using the same three screws and gasket secure the air duct adaptor in position.
Fig. 6
Fig. 5
40
90
Air duct adaptor
Flue duct adaptor
Boiler flue adaptor
Clamp and seal
Top of boiler
Cover plates
Alpha 240 Range, 280E
Alpha 500E
190
145
90
160
75
280
425
175
160
280
225
225
175
55
120
120
135
Air duct adaptor
may be fitted right
or left side