background image

5

704-939-B1-001, Rev. A 

(09/2020)

Initial Power-Up and Test / Returning the Unit to Service

1. Plug the power supply into the AC outlet.
2. Switch battery breaker ON.
3. The transponder LEDs will all blink in unison upon initial power up. The RDY LED will then begin blinking steadily

indicating normal processor activity.

4.

Verify the DS and OL LEDs are on solid. This verifies the Communications Module has registered an IP address

on the network.

5.

Verify the RF LED is solid Green, indicating Upstream and Downstream Power is within the default specified

range and the Upstream RF Power is below the recom50 dBmV (Table 1).

6. Verify no XM3 alarms are active.

Table 1, RF Power Default Values

Test Connection

XM3 Smart Display - COMM Menu:

Verify the DM3.0 Series transponder communication parameters such as IP address, RF Power Levels and

Signal/Noise Ratio on the COMM menu of the XM3 Smart Display. Press Enter <ENTR> to open the COMM-

GENERAL Menu enabling the operator to view values for communications parameters. Pressing the up or

down arrow softkeys will show two lines of information for each submenu item (Fig. 7).

Fig. 7, XM3 Smart Display Screen

RF Power Default Values

LED Color

Rx Range (dBmV)

Tx Range (dBmV)

Green

+10 to -10

0 to +50

Blue

+15 to +10 and -10 to -15

+50 to +55

Red

>+15 and <-15

>+55

COMM-GENERAL

CM MAC ADDRESS

00:90:EA:A0:04:99

ESC

COMMS STATUS/MENU

CM MAC ADDRESS

00:90:EA:A0:04:99

CM IP ADDRESS

192.168.1.121

CM IPV6 ADR PREFIX

2001:123:456:789

CM IPV6 ADR POSTFIX

111:222:333:3434

CPE MAC ADDRESS

00:90:EA:00:52:33