Quick Installation Guide 

SNX-60x0-486F Series Data Center Switch 

 

The figure below illustrates how to install the 

frontal rack-mount brackets

 onto the switch. 

1.

 

Place the switch on a flat horizontal surface. 

2.

 

Position the frontal rack-mount bracket over the screw 
holes on the side of the switch. The ears of the bracket 
must be facing forward and outwards. 

3.

 

Use the frontal rack-mount screws and the Phillips-
head screwdriver to fasten the bracket onto the side of 
the switch. 

4.

 

Repeat steps 1 to 3 for the other frontal rack-mount 
bracket on the other side of the switch. 

 

Figure 2 - Front Rack-Mount Bracket Installation 

The figure below illustrates how to install the 

rack-

mount slider brackets

 onto the rack-mount unit. 

5.

 

Take one rack-mount slider bracket and position it over 
the screw holes, on the back of the rack-mount unit, at 
the appropriate height. The ears of the bracket must be 
facing backwards and outwards. 

6.

 

Use the rack-mount unit screws and the additional 
screwdriver to fasten the bracket onto the back of the 
rack-mount unit. 

7.

 

Take the second rack-mount slider bracket and repeat 
steps 1 and 2, on the opposite side of the back of the 
rack-mount unit. Make sure to horizontally align the 
two rack-mount slider brackets. 

 

Figure 3 - Attach rack-mount slider brackets to rack 

The figure below illustrates how to mount the switch 
onto the rack-mount slider brackets. 

8.

 

Position the switch so that the rack-mount slider 
brackets align horizontally within the two rows of rack-
mount slider bracket pegs found on the side panel of 
the switch. 

9.

 

Slide the switch carefully backwards so that the rack-
mount slider brackets fit into the space between the 
two rows of rack-mount slider pegs. 

 

Figure 4 - Slide switch into position 

The figure below illustrates how to complete the 
rack-mount installation. 

10.

 

Use the rack-mount unit screws and the additional 
screwdriver to fasten the frontal rack-mount brackets 
onto the front of the rack-mount unit. 

 

Figure 5 - Slide switch into position 

Installing Transceivers into the 

Transceiver Ports 

Switches in this series have 48 SPF+ ports and 6 
QSFP+ ports. QSFP+ technology allows a smooth 
transition from 10 to 40 Gigabit Ethernet 
infrastructures in data centers. Each of the switch’s 
QSFP+ ports can operate in either native 40 Gigabit 
Ethernet mode or 4 x 10 Gigabit Ethernet mode. 
This switch supports both fiber and copper cabling 
solutions for these two modes. 

 