background image

BASE SOFT LIGHT A8-PLUS-J 

USER MANUAL 

December. 2019 

Summary of Contents for A8-PLUS-J

Page 1: ...BASE SOFT LIGHT A8 PLUS J USER MANUAL December 2019 ...

Page 2: ... as safety helmet during work 3 Be sure to fix the safety chain on the product when installing and moving 4 Please install the signs below for people to bypass when install the product on high truss 5 The work should be done under the direction of approved specialist who is trained in safety and mechanical installations WARNING 2 ...

Page 3: ...Menu Tree 14 Setting Product Information 15 DMX Mode Channel Change 16 DMX Mode Address Setup 16 User Mode Setup 17 User Mode Intensity CCT Tint Adjust 17 Color Mode Setup 18 Color Mode RGB Saturation Intensity Adjust 18 Sleep Mode Function 19 Master Function 19 RDM On Off Setup 19 Dimming Speed Setup 19 Fixture ID Setup 20 RDM Fixture Label Setup 20 Error Information Temperature Sensor 21 Network...

Page 4: ...d not exposed to elements A Plus Series is possible to express 2 500 10 000K color temperature and full color by combining LED which can control color temperature and RGB LED so it is used to create various sets of atmosphere A Plus Series that uses high efficiency CRI LED light sources can increase lifetime and reduce maintenance cost and power consumption 4 ...

Page 5: ...Fixture Exterior View Stirrup Smart Touch LCD Screen Handle Fixed Knob 5 Barn Door Connector Panel Clamp ...

Page 6: ...mm inch Dimensions A8 Plus 6 ...

Page 7: ...pply Range AC 100 240V 50 60Hz Power Consumption 400W White Light CCT Full 2 500 10 000K VCT Colored Light Full RGB W 4 Color gamut with Hue and Saturation control CRI 95 98 Dimming 0 100 16 bit Control 5 PIN DMX In and Out Smart Touch LCD Controller RDM Option Wireless DMX512 Wireless RDM Remote Device Management Supported Ambient Temperature Operation 20 45 C IP Rating IP20 Estimated LED Lifetim...

Page 8: ...Door Assembly Fit the bottom of the barn door into the groove on the top of the body Slide the barn door along the groove Fit the bolt on the upper barn door to the groove Turn the bolt clockwise to fix it 8 ...

Page 9: ...ser Lens Change Pull back the latches across the diffuser lens Pull out the diffuser lens to the left 9 When replacing the diffuser lens insert it with the smooth side facing inward Rough side facing forward ...

Page 10: ...3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged Power Connection AC power at 100 240V 50 60Hz 10 1 USB PORT for ADMINISTRATOR ONLY 2 POWER OUT 3 POWER IN 4 DMX OUT 5 DMX IN 6 POWER ON OFF SWITCH Do not connect USB without administrator s permission 1 2 3 4 5 6 ...

Page 11: ...e for connect the DMX controller to other XLR output 1 Shield 2 Signal 3 Signal 4 Not Connected 5 Not Connected Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture and connect one output to the input of the next fixture until all fixtures are connected In the last lighting fixture the DMX cable must be end with a terminator 120 Ω resistor in DMX o...

Page 12: ... Locked Fixture ID Screen Locked When the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset A A A ...

Page 13: ... 8 Home Return to the main screen 9 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 Color Mode Setup Set RGB lighting color Saturation and Intensity 12 Setting Setting or changing the function of the equipment 13 Fixture ID Displays numbers for equipment management 14 Equipment Information Displays the help that describes the ...

Page 14: ...ation Description of fixture ID Θ Information Basic equipment information Θ Rotate Θ Home Main Screen Θ DMX512 Mode DMX mode select DMX address input Θ Information DMX channel value Θ User Mode Intensity setup Color temperature setup Tint value setup Θ Information Description of each function Θ Color Mode RGBW color setup Saturation setup Intensity setup Θ Information RGBW value Menu Tree 14 ...

Page 15: ...tail information which manufacturer model name firmware version UID number current fixture temperature power hours LED hours website and product manual download link by selecting INFORMATION button in main screen Product Information 15 ...

Page 16: ... used to adjust by DMX512 signal 1 1 Ch mode Dimming 3 3 Ch mode Dimming CCT Tint 5 5 Ch mode Dimming CCT Tint Cross Fader Color Macro 8 8 Ch mode Dimming CCT Tint Cross Fader Red Green Blue White Pressing the Info button in DMX512 MODE displays each channel information and value To return to the previous screen press the Info button again Support channels and features vary by product DMX Mode Cha...

Page 17: ...User Mode It is used when the user directly manipulates the equipment Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperature value of the fixture and is displayed from 2 500 to 10 000K Tint The number indicates the current tint gamma value of the fixture and is displayed from 1 00 Magenta to 1...

Page 18: ...or drag the color user want Hue Drag and select the Hue user want Saturation The number indicates the current saturation value of the fixture and is displayed from 0 to 100 White The number indicates the current White LED brightness value of the fixture and is displayed from 0 to 100 Pressing the Info button in COLOR MODE displays description of each function To return to the previous screen press...

Page 19: ...hat allows user to synchronize and control all fixtures without a console connection The default is off which means the fixture follows the instructions of the console Dimming speed setup The number indicates the current dimming speed value of the fixture and is displayed from 0 to 40 The higher the value the slower the dimming speed and 15 is default speed Pressing the Info button in SETTING disp...

Page 20: ...sh and the management number in the Device Label field The entered contents are displayed in the upper left corner The fixture ID is automatically displayed in 3 or 4 digits from automatically recognized 4 digits in contents If user do not enter any number the fixture ID is displayed as 001 Pressing the Info button in FIXTURE ID displays description of the function It is the number value 001 to 99...

Page 21: ...and Temperature Error Please Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Temperature Sensor When the DMX512 network connection is lost the DMX512 address number in main screen and the fix...

Page 22: ...el 3 is 255 only Red channel 4 Green channel 5 Blue channel 6 and White channel 7 color values are displayed As the DMX value of channel 3 Cross Fader increases RGB and White values become darker The DMX value of channel 3 adjusts relatively the brightness ratio of channel 2 and channel 4 7 Color Macro Channel 4 is Color Macro express rainbow gradation effect The order is Red Green Blue 22 ...

Page 23: ...0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 0 100 Color Macro 8 1 0 255 0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 0 100 Red 6 0 255 0 100 Green 7 0 255 0 100 Blue 8 0 255 0 100 White 23 DMX Protocols 1 3 ...

Page 24: ...nction 118 5950 119 120 6000 121 122 6050 123 124 6100 125 6150 126 127 6200 128 129 6250 130 6300 131 132 6350 133 134 6400 135 6450 136 137 6500 138 139 6550 140 141 6600 142 6650 143 144 6700 145 146 6750 147 6800 148 149 6850 150 151 6900 152 6950 153 154 7000 155 156 7050 DMX Value Function 157 158 7100 159 7150 160 161 7200 162 163 7250 164 7300 165 166 7350 167 168 7400 169 7450 170 171 750...

Page 25: ... Value Output Value Function 3 0 10 0 No Effect 11 20 1 00 Full Magenta 21 119 0 99 0 01 99 1 Magenta 120 145 0 No Effect 146 244 0 01 0 99 1 99 Green 245 255 1 00 Full Green DMX Protocols 3 3 Channel 3 Tint 25 ...

Page 26: ...S YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPTION YES STATUS_MESSAGES YES Lamp Controls No Control Property Value Example Description User Settings Remarks 1 Identify On N A Device identification action active Enable Identify device Same as On 2 Identify Off N A Device identification action inactive Enable Identify device Same as Off 3 Cold Reset N A ...

Page 27: ...X Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display only no actual response 10 Lamp On Mode N A N A Display only no actual response 11 Display Invert On LCD screen display direction Enable Off 0 On 180 Auto Current opposite direction 12 Identify Device Off Selected ...

Page 28: ...cription 8 Ch Model Device RGB 1 Ch Mode 1 Ch Mode 3 Ch Mode 3 Ch Mode 5 Ch Mode 5 Ch Mode 8 Ch Mode 8 Ch Mode 1 Ch 2500K 1 Ch Mode 2500K Color Temperature 1 Ch 2900K 1 Ch Mode 2900K Color Temperature 1 Ch 3000K 1 Ch Mode 3000K Color Temperature 1 Ch 3500K 1 Ch Mode 3500K Color Temperature 1 Ch 4000K 1 Ch Mode 4000K Color Temperature 1 Ch 4500K 1 Ch Mode 4500K Color Temperature 1 Ch 5000K 1 Ch Mod...

Page 29: ... information and questions please visit our website or call ALPHA LITE Co Ltd 2nd Floor 5 8 Gyeongin ro 88 gil Yeongdeungpo gu Seoul Republic of Korea 07363 Email Tel Fax Web hello alpha lite net 82 2 6317 0464 82 2 2039 0464 www alpha lite net ...

Reviews: