Installation and assembly

Observe the following when performing all work:

 NOTICE.

 

Always comply with applicable accident pre-
vention regulations, statutory regulations, ordi-
nances and directives.

INSTALLATION LOCATION

 ATTENTION

 

Install the unit only indoors.

The installation area must be frost-free and dry. It must 
fulfill applicable local regulations.

  Dimensional drawing and installation plan for re-

spective unit model.

TRANSPORT TO INSTALLATION LOCATION

To avoid damage during transport, you should transport 
the unit to the final installation location in its original 
packaging (with angle bracket on the wooden pallet), us-
ing a lifting truck.

 CAUTION!

 

Several people are required to transport 
the unit. Do not underestimate the weight 
of the unit.

 Overview “Technical data/scope of delivery”, 

“General unit data” section.

 CAUTION!

 

Unit is not fastened to the wooden pallet. 
The unit can tip when being lifted down 
and during transport with a lifting truck.  
This can result in personal injury and dam‑
age to the unit.

–  Take suitable precautionary measures 

to eliminate the danger of tipping.

If it is not possible to transport the unit to the final in-
stallation location using a lifting truck, you can also 
transport the unit using a hand truck.

 ATTENTION

 

Never use components and hydraulic connec-
tions on the unit for purposes of transport.

 ATTENTION

 

Do not damage the components and hydraulic 
connections under any circumstances.

 DANGER!

 

The strap attached to the back of the unit 
is an aid for tipping the unit onto a hand 
truck! Always secure the unit on the hand 
truck with a tension belt!

 

Do not lift or transport the unit using only 
the strap!

–  The strap could break
–  Persons could be injured
–  Persons beneath the load could be fa‑

tally injured

–  The unit and other objects could be 

damaged!

 CAUTION!

  

Wear safety gloves.

INSTALLATION

 CAUTION!

 

Several people are required to install the 
unit. Do not underestimate the weight of 
the unit.

Proceed as follows at the installation location:

  Set unit on a solid and level, preferably sound-insu-

lated surface…

  Mount feet…

 ATTENTION

 

Moving the unit without the feet mounted can 
damage the floor.

Summary of Contents for Hydraulic tower HT 1

Page 1: ...UK 83054000dUK Translation into English of the original German operating manual Operating Manual Hydraulic tower HT 1 Hydraulic tower HT 2 Accessories for Air Water Heat Pumps Outdoor Installation...

Page 2: ...he pa rameters for the respective model This operating manual is intended only for persons as signed to work on or operate the unit Treat all con stituent parts confidentially The information containe...

Page 3: ...llation Hydraulic connection to heating circuit 9 Safety component 10 Hydraulic connection of hot water tank 10 Expansion vessels 10 ELECTRICAL CONNECTIONS 10 RINSING FILLING AND BLEEDING THE SYSTEM 1...

Page 4: ...and its compo nents in an improper manner if work is performed on the unit that is not de scribed in this operating manual and this work was not expressly approved in writing by the man ufacturer if...

Page 5: ...hot water in the building In heat pumps with heat quantity recording the analysis is conducted by the regulator The regulator displays the thermal energy that is exchanged from the heating system in...

Page 6: ...will conduct the required maintenance at regular intervals Malfunctions In the event of a malfunction you can detect the cause of the malfunction via the diagnostic program of the heating and heat pum...

Page 7: ...g lifted down and during transport with a lifting truck This can result in personal injury and dam age to the unit Take suitable precautionary measures to eliminate the danger of tipping If it is not...

Page 8: ...unit at final location Compensate for minor unevenness using the four adjusting screws Then tighten the lock nuts COMPONENTS OF THE UNIT 1 Safety component for heating circuit insulated 2 Hot water t...

Page 9: ...account the connecting lines between the heat pump and the hydraulic tower ATTENTION Install hot water connections to the heat pump based on the specifications of the heat pump guide below frost pene...

Page 10: ...he cable duct to the terminals in the switch cabi net Follow specifications of the terminal diagram for electrical connections Terminal diagram for respective model SAFETY COMPONENT The safety compone...

Page 11: ...hrough the unit when installing the connections and run it through the front facade of the unit parallel to the already present heating and heat pump regulator control cable NOTICE If electric heating...

Page 12: ...arting position and mount the motor of the 3 way valve NOTICE To ensure a good seat of the motor on the valve make sure that the U bolt with the reduction is not pushed past the lug because then the m...

Page 13: ...n on motor of 3 way valve and simulta neously turn adjusting lever 90 Rinse heating circuit If necessary heating and hot water circuit can be rinsed at the same time To do so press button on motor of...

Page 14: ...t pump controller Shut off valves to the heating circuit Ensure that the total flow is routed via the overflow valve Read out the flow and return temperature at the heating and heat pump controller Op...

Page 15: ...NOTICE A connection to a computer or a network can be installed via the left bushing on the bottom of the control element thus allowing the heat ing and heat pump regulator to be controlled remotely O...

Page 16: ...of delivery 1 recess for control element 2 logo 3 temporary cover First insert the screen below in the provided slots on the front of the facade Beginning first on one side and moving upwards lock the...

Page 17: ...onents in accordance with the applicable regulations standards and directives REMOVAL OF THE BUFFER BATTERY ATTENTION Before scrapping the heating and heat pump reg ulator remove the buffer battery on...

Page 18: ...unit data Dimensions see dimensional drawings for the specified unit size unit size Total weight kg Connections Heating circuit Cold water hot water Circulation Electric Voltage code circuit breaker c...

Page 19: ...of the original German operating manual ait deutschland GmbH HT 1 0 70 1000 3 98 295 10 2 1 290 R 1 R 1 R 1 RP 1 N PE 230V 50Hz B10 0 07 20 25 1 5 0 3 35 49 813300a HT 2 0 52 2000 3 98 285 10 3 5 1 2...

Page 20: ...HT 1 Zeichnungsnummer 812022 Datei 812022b Externe Pressung HT 1 PEP 021 2006 Stannow 22 06 07 a M 0072 2015 Liska 25 01 2015 b M 001 2016 Liska 25 02 2016 nd M Ersteller Datum 0 0 0 1 0 2 0 3 0 4 0...

Page 21: ...ssung Seite 1 1 HT 2 Zeichnungsnummer 812023a Datei 812023a Externe Pressung HT 2 PEP 021 2006 Stannow 22 06 07 a M 013 2013 Li ka 17 06 2013 nd M Ersteller Datum 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0...

Page 22: ...view from left E Rear view HT 1 HT 2 1 Control element 2 Safety component in extra box Rp Rp 3 Ducts for electric sensor cables 4 hot water R 1 R 1 5 Hot water inflow return flow R 1 R 1 6 Hot water o...

Page 23: ...nglish of the original German operating manual ait deutschland GmbH Legend UK819290 All dimensions in mm RH Minimum room height 2100 OKF Top edge of finished floor D 20 Distance to next object FS Shad...

Page 24: ...24 Subject to change without notice 83054000dUK Translation into English of the original German operating manual ait deutschland GmbH Hydraulic integration with LW 71A LW 180A...

Page 25: ...Dirt trap 0 6 mm mesh 15 Mixer circuit three way mixer MK2 3 discharge 30 Spill tray f r brine mix 100 Room thermostat for cooling optional 17 Temperature difference regulator 31 Wall breakthrough 10...

Page 26: ...ontrol line Diverting valve for domestic hot water internally wired TRL Terminal strips on controller board see sticker A3 11 3 ZUP GND Charge discharge cooling mixer 1 closed 8 BUP K14 Contactor elec...

Page 27: ...pump not applicable with optional integrated heat quantity meter Legend Y1 EVU Connection for impressed current anode X2 T1 X7 Domestic hot water sensor Supply terminals in switchbox of hydraulic tow...

Page 28: ...eter 2 Controller supply 3 230VAC X2 1 EVU UK817318 Operating materials A1 1 N PE 230V 50Hz EVU Diverting valve for domestic hot water Energy supplier contact closed on release bridge if no blocking i...

Page 29: ...29 Subject to change without notice 83054000dUK Translation into English of the original German operating manual ait deutschland GmbH...

Page 30: ...30 Subject to change without notice 83054000dUK Translation into English of the original German operating manual ait deutschland GmbH...

Page 31: ...31 Subject to change without notice 83054000dUK Translation into English of the original German operating manual ait deutschland GmbH...

Page 32: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf E info alpha innotec de W www alpha innotec de alpha innotec an ait deutschland GmbH brand UK...

Reviews: