background image

System Display and Controller

Summary of Contents for Out Back Power MATE Series

Page 1: ...System Display and Controller ...

Page 2: ... Setup 3 MATE System Display and Controller AGS Menu 4 5 Inverter Setup 6 7 Charge Controller Setup 8 FLEXnet DC Setup 9 10 900 0131 01 00 Rev A vsd TOC 2012 03 21 2012 OutBack Power Technologies All Rights Reserved WARNING SHOCK HAZARD Consult the MATE Owner s Manual for detailed information on safety and installation procedures ...

Page 3: ... SEARCH search 6 sensitivity DOWN INC DEC PORT Port MAIN 3 02 14P SUM STATUS SETUP ADV Main Screen Main Menu Soft Keys To cycle through the devices connected to the HUB press the PORT soft key Select this option to proceed Available menus Adjusts the set points value Switches between devices on the ports of the Communications HUB Soft Key Color Code Navigation colors Selects a function e g ON OFF ...

Page 4: ... VIEW RSET 00 000 01 000 02 000 03 000 04 000 05 000 06 000 07 000 08 000 09 000 10 000 2M 000 After Resetting Comm Errors SETUP MATE PAGE2 choose category PG1 SUMRY COMM PG3 SETUP MATE PAGE3 choose category PG2 BEEP MAIN SETUP MATE COMM Choose category BACK REPOLL PC DEBUG 00 000 01 000 02 000 03 000 04 025 05 001 06 001 07 001 08 001 09 001 10 001 2M 001 Viewing Comm Errors 1 1 2 3 4 5 6 Setting...

Page 5: ...ctory Defaults 1 1 The AGS Menu is shown on the next page ADV MATE DEFAULT Are you sure YES NO ADV MATE GRIDUSE weekday 12 00A griduse start time DOWN UP CHANGE ADV MATE GRIDUSE weekday 12 00A griduse stop time DOWN UP CHANGE ADV MATE GRIDUSE weekend 12 00A griduse start time DOWN UP CHANGE ADV MATE GRIDUSE weekend 12 00A griduse stop time DOWN UP CHANGE WEEKDAY GRIDUSE START adj hour 12 00A DOWN ...

Page 6: ...e start DOWN UP CHANGE ADV MATE AGS QUIETTIME weekend 12 00A quiet time stop DOWN UP CHANGE ADV MATE AGE QUIETTIME end of quiet time menu UP TOP AGS ADV MATE AGS VSTART volt start 24 4 Vdc 24 hr setting DOWN AGS INC DEC ADV MATE AGS VSTART volt start 23 6 Vdc 2 hr setting DOWN UP INC DEC ADV MATE AGS VSTART volt start 22 0 Vdc 2 min setting DOWN UP INC DEC ADV MATE AGE QT end of VOLTAGE START menu...

Page 7: ...j min 12 00A INC DEC DONE ADV MATE AGS SOC end of SOC START Menu UP TOP AGS ADV MATE AGS PAGE3 choose category soc PG2 START TIMERS PG4 ADV MATE AGS TIMERS ags state 0 DOWN AGS ADV MATE AGS TIMERS agsgenfault 0 DOWN UP ADV MATE AGS TIMERS 24 hr 1440 min vs time DOWN UP ADV MATE AGS TIMERS 2 hr vs time 120 min DOWN UP ADV MATE AGS TIMERS 2 min 2 min vs time DOWN UP ADV MATE AGS TIMERS lsstart timer...

Page 8: ...RTER P01 search 8 pulse length DOWN INC DEC PORT ADV FX INVERTER P01 search 8 cycles pulse length DOWN INC DEC PORT ADV FX INVERTER P01 search 60 cycles pulse spacing DOWN INC DEC PORT ADV FX INVERTER P01 low battery 21 0 Vdc cutout set point DOWN INC DEC PORT ADV FX INVERTER P01 low battery 25 0 Vdc cutin set point DOWN INC DEC PORT ADV FX CHARGER P01 float 1 0 hrs time limit DOWN INC DEC PORT AD...

Page 9: ... FX AUX P01 aux output setup completed TOP ADV MAIN ADV FX PAGE3 P01 choose category PG2 AUX STACK PG4 ADV FX AUX P01 aux output AUTO control DOWN INC DEC PORT ADV FX AUX P01 aux output cool fan function DOWN INC DEC PORT ADV FX AUX P01 genalert 22 0 Vdc on setpoint DOWN INC DEC PORT ADV FX AUX P01 genalert 4 min on delay DOWN INC DEC PORT ADV FX AUX P01 genalert 28 0 Vdc off set point DOWN INC DE...

Page 10: ...ORT ADV FX CHRG P02 end charger menu TOP ADV MAIN ADV CC ADVANCED P02 snooze mode 0 6 AMP DOWN INC DEC PORT ADV CC ADVANCED P02 wakeup mode VOC change 3 0 V DOWN INC DEC PORT ADV CC ADVANCED P02 wakeup mode time 5 minutes DOWN INC DEC PORT ADV CC ADVANCED P02 MPP range limit VOC minimum 1 2 DOWN INC DEC PORT ADV CC ADVANCED P02 absorb time 1 0 hours DOWN INC DEC PORT ADV CC ADVANCED P02 absorb end...

Page 11: ...RESET TOP STATUS DC SHUNT B max charged kWatts 2 040 DOWN UP RESET TOP STATUS DC BATT total days at 100 0 5 DOWN UP RESET TOP STATUS DC BATT days since charge parameters met 5 9 DOWN UP TOP STATUS DC BATT battery min today 24 8 Vdc DOWN UP RESET TOP STATUS DC SHUNT B max charged amps 39 8 DOWN UP RESET TOP METER DC SHUNT B removed 0 AH 0 kWH DOWN UP TOP METER DC SHUNT B charged 12 AH 0 16 kWH DOWN...

Page 12: ...TOP ADV DC AUXCONTROL low volts 22 0 Vdc DOWN INC DEC TOP ADV DC AUXCONTROL SOC high 90 DOWN INC DEC TOP ADV DC AUXCONTROL SOC low 59 DOWN INC DEC TOP ADV DC AUXCONTROL high set point delay 1 minutes DOWN INC DEC TOP ADV DC AUXCONTROL low set point delay 1 minutes DOWN INC DEC TOP ADV DC AUXCONTROL invert logic YES DOWN YES NO TOP ADV DC AUXCONTROL aux parameters complete TOP ADV MAIN Accessing th...

Page 13: ...TY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK Warranty Summary OutBack Power Technologies warrants that the products it manuf...

Page 14: ...1 3 0 0 1 9 1 9 1 1 ...