Alpha Communications RD-GB2/A User Manual Download Page 36

36

BUS

BUS

BUS

BUS

D

C

B

A

DP-

2

GB A

End of line

OFF

AP

AP

ON

1     2    3     4     5     6

SW1

ON

1     2    3     4     5     6

SW1

AP

ON

1     2    3     4     5     6

SW1

(1)

(1)

(1)

Video door entry system: To the distributors (building floors)
Audio door entry system: To the telephones (building floors)

Lock release

max. 12 Vdc/270mA.

Lock release

max. 12 Vdc/270mA.

Lock release

max. 12 Vdc/270mA.

NA2

+

AP-

C1 NA1

AP+

C2 AP+ AP- P1 P2 BUSBUS

Relay 2

Relay 1

_

12Vdc

NA2

+

AP-

C1 NA1

AP+

C2 AP+ AP- P1 P2 BUSBUS

Relay 2

Relay 1

_

12Vdc

NA2

+

AP-

C1 NA1

AP+

C2 AP+ AP- P1 P2 BUSBUS

Relay 2

Relay 1

_

12Vdc

Important:

For description, installation, configuration and programming of the door panel, see the respective manual.

To connect more than one button access panel, see characteristics page 3.

(1)

(1)

(1)

( )

2

Installation of a video door entry system with

access panels, DP-GB2A distributor for door panels and

4

Golmar DC lock release.

WIRING DIAGRAMS:

Mains

100~240Vac

N

L

CN

BUS (M) BUS(PL)

FA-

2

GB /A

L

Video door entry system: Leave the end of line in
the OFF position.
Audio door entry system: Set the end of line to ON.

(  )

*

Important: (in this distributor).

(  )

*

Access panel

2

Button panel

Coded panel

Access panel

1

Button panel

Coded panel

Access panel

3

or

Button panel

Coded panel

( )

2

or

or

( )

2

( )

2

RD-GB2A BUS AMPLIFIER

AP

ON

1     2    3     4     5     6

SW1

(1)

Lock release

max. 12 Vdc/270mA.

NA2

+

AP-

C1 NA1

AP+

C2 AP+ AP- P1 P2 BUSBUS

Relay 2

Relay 1

_

12Vdc

(1)

Access panel

4

Button panel

Coded panel

or

( )

2

Important:

For the connection of an AC lock release or a 2nd lock release, see page 37.

(1)

Summary of Contents for RD-GB2/A

Page 1: ...MANUAL AWD260 REV 12 2017 RD GB2 A GB2 Bus Amplifier Repeater TECHNOLOGY 42 Central Drive Farmingdale NY 11735 1202 P 631 777 5500 F 631 777 5599 Toll Free 1 800 666 4800 http www alphacommunications...

Page 2: ...9 10 Description of the function buttons 11 16 Door panel call addresses and monitor addresses assigned to each RD GB2Amodule 17 20 Configuring the button code up to 32 addresses apartments 21 30 Conf...

Page 3: ...single button on each door panel Installation with 3 door panels with pushbuttons up to 42 apartments double button 21 apartments single button on each door panel Installation with 4 door panels with...

Page 4: ...1m A1 80m 80m 1m Cable 60m B1 80m D2L 2 GB A C B C D VESTA2 FA 2 GB A VESTA2 G 2 B Building installation D2L 2 GB A1 C B1 C VESTA2 FA 2 GB A VESTA2 GB2 Building installation with RD GB2A on monitor b...

Page 5: ...or panel w Installation with 3 door panels with pushbuttons up to 42 apartments double button 21 apartments single button on each door panel wInstallation with 4 door panels with pushbuttons up to 32...

Page 6: ...ng up to 3 access panels OPERATING MODES Gateway operating mode FA 2 GB A FA 2 GB A D2L 2 GB VESTA2 A1 12 Vdc 270mA RD GB2A N 8 VESTA2 FA 2 GB A D2L 2 GB VESTA2 A1 VESTA2 FA 2 GB A D2L 2 GB VESTA2 A1...

Page 7: ...system DIN rail latch release Bus input terminals e f g The RD GB2A module can be mounted onto a DIN rail 4 elements by applying slight pressure To remove the RD GB2A module from the DIN rail use a f...

Page 8: ...addresses 64 to 95 for monitor address 0 to 31 respectively Coded panel call addresses 65 to 96 for monitor address 0 to 31 Note Call address 96 on the coded panel calls the monitor with address 0 1 2...

Page 9: ...dby The RD GB2A module has the following status LEDs Description of the function buttons Displaying video gain Gai 1 n Gai 2 n Gai 3 n Gai 4 n Gai 5 n Gai 6 n ON OFF OFF OFF ON OFF ON ON OFF OFF OFF O...

Page 10: ...FF ON ON OFF ON OFF ON ON Bus IN LED Bus OUT LED Tx Rx LED Video gain Continued from previous page Set the video gain to fixed or automatic mode The RD GB2A module has 2 operating modes for setting ga...

Page 11: ...n P7 27 Add Button P8 28 Add Button P9 29 Add Button P10 30 Add Button P1 1 Add 3 Button Monitor address RD GB2A module No 1 Monitor address Coded panel address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1...

Page 12: ...P3 Add 53 Button P4 Add 54 Button P5 Add 55 Button P6 Add 56 Button P7 Add 57 Button P8 Add 58 Button P9 Add 59 Button P10 Add 60 Button P1 Add 61 Button 7 EL610D module No P2 6 Add 2 Button P3 6 Add...

Page 13: ...utton P5 8 Add 5 Button P6 8 Add 6 Button P7 8 Add 7 Button P8 8 Add 8 Button P9 8 Add 9 Button P10 9 Add 0 Button P1 9 Add 1 Button 10 EL610D module No P2 9 Add 2 Button P3 9 Add 3 Button P4 94 Add B...

Page 14: ...d Button P8 118 Add Button P9 119 Add Button P10 120 Add Button P1 12 Add 1 Button 13 EL610D module No P2 12 Add 2 Button P3 123 Add Button P4 124 Add Button P5 125 Add Button P6 126 Add Button P7 127...

Page 15: ...160 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 RD GB2A module No 6 0 6 IMPORTANT In coded panel systems N3301 GB2 on t...

Page 16: ...22 23 24 25 26 27 28 29 30 31 224 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 4 2 IMPORTANT In coded panel systems N330...

Page 17: ...11 31 21 DIP switch On Off Off Off Off On Off On Off Off Off Off Off Off Off Off Off Off Off Off Off On On On Button code P2 P3 P4 P5 P6 P7 2 22 12 3 23 13 4 24 14 5 25 15 6 26 16 7 27 17 8 28 18 9 2...

Page 18: ...5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 4 5 6 ON NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc 1 2 Front Back VESTA2 V...

Page 19: ...de P1 Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP...

Page 20: ...DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 Co 25 de Co 24 de Co 23 de Co 22 de Co 21 de Co 30 de Co 29 de Co 28 de Co 27 de Co 26 de Co 31 de 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4...

Page 21: ...5 36 37 38 39 40 5 51 Off Off Off Off On Off Off On 42 43 44 45 46 47 48 49 50 6 61 Off Off Off Off Off On Off On 52 53 54 55 56 57 58 59 60 7 71 Off Off Off Off Off Off On On 62 63 64 65 66 67 68 69...

Page 22: ...Off Off Off Off Off Off Off Off On Off Off Off On Off Off Off Off Off Off Off Off Off Off On Off Off Off On Off Off Off Off Off Off Off Off Off Off On Off Off Off On Off Off Off Off Off Off Off Off Of...

Page 23: ...DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 4 5 6 ON NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vd...

Page 24: ...de Co 8 de Co 7 de Co 6 de Co 5 de Co 4 de Co 3 de Co 2 de 1 2 3 ON DIP 4 5 6 Code 11 Code 20 1 2 3 ON DIP 4 5 6 Code 19 Co 18 de Co 16 de Co 14 de 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4...

Page 25: ...5 6 1 2 3 ON DIP 4 5 6 Code 15 Code 13 Code 12 1 2 3 ON DIP 4 5 6 Code 21 Code 30 1 2 3 ON DIP 4 5 6 Code 29 Code 28 1 2 3 ON DIP 4 5 6 Code 27 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 Code 25 Code 23 1...

Page 26: ...2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 Code 20 Code 19 Code 18 Code 17 Code 16 1 2 3 ON DIP 4 5 6 Code 21 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 1 2 3 ON DIP 4 5 6 Co...

Page 27: ...EL632 GB2A Co 5 de Co 4 de Co 3 de Co 2 de Co 1 de Co 10 de Co 9 de Co 8 de Co 7 de Co 6 de Co 15 de Co 14 de Co 13 de Co 12 de Co 11 de Co 0 de RD GB2A BUS AMPLIFIER INSTALLATION In door panel syste...

Page 28: ...ode C 19 ode C 18 ode C 17 ode C 16 ode C 25 ode C 24 ode C 23 ode C 22 ode C 21 ode C 30 ode C 29 ode C 28 ode C 27 ode C 26 ode C 35 ode C 34 ode C 33 ode C 32 ode C 31 ode RD GB2A BUS AMPLIFIER IN...

Page 29: ...0 de Co 39 de Co 38 de Co 37 de Co 36 de Co 45 de Co 44 de Co 43 de Co 42 de Co 41 de Co 50 de Co 49 de Co 48 de Co 47 de Co 46 de Co 55 de Co 54 de Co 53 de Co 52 de Co 51 de RD GB2A BUS AMPLIFIER IN...

Page 30: ...610D Monitor code Co 60 de Co 59 de Co 58 de Co 57 de Co 56 de Co 65 de Co 64 de Co 63 de Co 62 de Co 61 de Co 70 de Co 69 de Co 68 de Co 67 de Co 66 de RD GB2A BUS AMPLIFIER INSTALLATION Module No 13...

Page 31: ...ER 31 N 1 AP 2 NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc ON 1 2 3 4 5 6 SW1 Coded panel 2 Button panel Configure the end of line on the last monitor RD GB2A DIP 6 to ON Remove the...

Page 32: ...Important Note Cross sections and distances table see page 4 Mains 100 240Vac N L CN BUS M BUS PL FA 2 GB A L or IN IN R GB A D 2 OUT DS BUS BUS BUS BUS D2 D1 D2L GB2 ON BUS BUS BUS BUS D2 D1 D2L 2 G...

Page 33: ...N 1 AP 2 NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc 2 Configure the end of line on the last monitor RD GB2A DIP 6 to ON Remove the jumper from all of the distributors except the l...

Page 34: ...AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc ON 1 2 3 4 5 6 SW1 2 AP 2 NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc ON 1 2 3 4 5 6 SW1 2 3 Button interior panel Config...

Page 35: ...P2 BUSBUS Relay 2 Relay 1 _ 12Vdc ON 1 2 3 4 5 6 SW1 2 AP 2 NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc ON 1 2 3 4 5 6 SW1 3 Coded interior panel 2 3 Coded interior panel Remove the...

Page 36: ...nual To connect more than one button access panel see characteristics page 3 1 1 1 2 Installation of a video door entry system with access panels DP GB2A distributor for door panels and 4 Golmar DC lo...

Page 37: ...AP2 Mains 230Vac Connection of Golmar DC and AC lock releases Important Place the varistor supplied with the sound module directly onto the terminals of the lock release Important Place the varistors...

Reviews: