TIMER II
Preset starting : press FONCTION button, an alarm is hear. “Set II “and “timer on” blink on the control
panel. Set the hour by pressing “+ and –” button. Press again FONCTION button to confirm the hour (now
the hour shines and minutes blink). Press “+ and -” to set the minutes, press again FONCTION button to
record the minutes. Timer II is activate.
For example : for a starting at 3pm, set “3:00”.
PRESET STOP :
press FONCTION button, an alarm is hear. “Set II “and “timer off” blink on the control panel. Set the hour by
pressing “+ and –” button. Press again FONCTION button to confirm the hour (now the hour shines and
minutes blink). Press “+ and -” to set the minutes, press again FONCTION button to record the minutes.
Timer II is activate.
For example : for a stop at 4pm, set “4:00”.
TO CANCEL TIMER :
To cancel timer I or timer II, follow the step of “Timer” part by setting “0:00” for start clock and “0:00” pour
stop clock. The timer indicators of control panel will switch off.
NOTE :
• “PM” indicator appears when the setting clock is on afternoon.
• The time ON and the time OFF must be preset synchronously; otherwise the preset time will be invalid.
• The time ON and the time OFF must be different (never same value).
• The timer I and timer II must not be overlapping.
• When the timer is activate, the light indicator is red. It will be green at the end of preset time.
• If the time set has been preset, the heater will operate as per the preset procedure, unless the preset
value are cancelled (cf timer part).
• After the time set has been preset, the heater will stop heating 3 seconds later.
Note : If the temperature is indicated in °F, press simultaneously “+” and “-” buttons to have temperature in
°C.
AUTOMATIC CUT-OFF
This appliance is equipped of an automatic cut-off device in case of overheating. This device allows to stop
the appliance when the heat inside the appliance’s body becomes too high. This cut-off stops the heating
element.
The appliance restart automatically when temperature reduces to a normal level.
C L E A N I N G
C L E A N I N G
• Switch off and unplug the appliance.
• The dust may be removed with a soft cloth or a vacuum cleaner.
• Clean the body with a soft, dry cloth (never immerse appliance in water), do not allow water to run into the
interior of the heater.
• When the heater is not use for a long time, protect it from dust and dry.
10