ALORAIR Storm SLGR 850C Installation And Operation Manual Download Page 5

3.4

Wifi hotspot: 

factory setting is "0FF", 

press > to enable wifi hotspot and switch 
ON/OFF.The device can transmit data and receive 
APP commands.The icon flickers when connected 
on the main interface. After successful connection,
the icon displays normally.

3.5.1

The power down time is adjusted according to">"
and the power down time increases from 3 to 20 
minutes (3-5-10-15-20), which is the so-called 
stop time of the fan after shutdown, in order to 
better drain the water.Factory set for 3 minutes.
(the other state of the fan is still 15 seconds.)

3.5.2

The

 

screen

 

displays

 

when

 

you

 

press

 

shut

 

down:

Indicates:

 

the fan is closed after a few minutes, 

and the standby page UNIT OFF is displayed after 
the fan is closed.

3.6

3.7

“Temp Units 

/

Used for temperature scale 

switching.Press the ">" button to switch 

℉/℃

after switch symbol of corresponding parts is also 
changing.

“MOISTURE CONTENT UNITS”

It is used to 

switch the unit of GPP value with moisture 
content. Press > to switch the Ib or Kg, after 
switch symbol of corresponding parts is also 
changing.

3.8

"

Humidistat Setpoint 00%

"

:Used for setting dehumidification 

mode humidity.Press ">" to set the humidity. The adjustment 
range of humidity setting is between 25 and 80%. 
Each key rises or falls 5%, which can be recycled. 

When the setting is completed,do not operate for 5 seconds 
and begin to take effect.(Otherwise, the compressor will be 
shut down immediately after it is below ambient humidity at 
the time of setting.) Humidity below 25 percents "CO" mode
recyclable.The main interface displays the set parameters

.

4. Main interface frosting status display:

The machine will display this after defrost when running

When the machine is running normally, “Deffrost 
SHUTDOWN IN 06:00” will occurs in the 
interface after defrosting. It’s defrost countdown
use seconds as units. This screen displays only 
3 seconds. Displays the previous interface and 
status after restoration.If it is the home screen, 
the frost icon will flash.

When the user is operating in the submenu, the 
machine is in the frosting state.At this point, the 
frosting interface displays 3 seconds, and returns 
to the submenu program in the background 
countdown.When the user returns to the main 
interface without any operation, the frosting state
is displayed inthe main interface in the way of 
icon flicker.

5. Compressor on waiting interface display

 

Compressor protection time not shown:

“Compressor  ready  IN 03:00”

 indicates : That the

interface will be displayed when the compression is
in a protected state. (

including power-on and shutdown,

the humidity rises immediately after the arrival of L0
HI, and the shutdown resumesimmediately after the 
emergence of L0 HI

).Displays the countdown in seconds.If the

above situation does not occur within 3 minutes, it is not
shown.