Owner’s Manual - Storm SLGR 1600X Dehumidi

er

Installation, Operation & Service Instructions

Add: 

2048 E. Francis St Ontario CA 91761

Tel: 1-888-990-7469    

E-mail: [email protected]

Alorair Solutions INC.

Summary of Contents for Storm SLGR 1600X

Page 1: ...Owner s Manual Storm SLGR 1600X Dehumidifier Installation Operation Service Instructions Add 2048 E Francis St Ontario CA 91761 Tel 1 888 990 7469 E mail sales alorair com Alorair Solutions INC ...

Page 2: ...cation Electrical Supply How the Strom LGR 1600X Works Guidelines Parts Diagram Using the Display Main Screen Using the Display Submenus Maintenance Instructions Error Codes Troubleshooting Dehumidifier Storage Warranty 11 10 10 9 8 6 4 3 2 2 1 1 1 ...

Page 3: ...ate of purchase You will need this information if you need assistance in the future The data label on the side of your unit has the necessary information Model Number Storm SLGR 1600X Serial Number Date of Purchase For additional questions concerning your dehumidifier Contact your installing contractor Contact Alorair Solutions Power Supply 110 120V 60 Hz AC Single Phase Outlet Requirement 3 Prong ...

Page 4: ...ed and stored on a stable surface For maximum efficiency operate the unit with all windows and doors closed Do not place the unit anywhere that may block the inlet or outlet airflow Drain Hose Notes The Storm SLGR 1600X is equipped with an external drain line connection making it easy to plug in The drain line can be directed outside or into any sink drain etc For more effective draining uncoil the en...

Page 5: ...Parts Diagram Temp RH sensor Air inlet Handle Air Filter Power line Control Panel Condensate Drain Line Quick Connect ...

Page 6: ... 5 between 35 and 90 The default humidity level is 50 Manual Drain Button Prior to moving or storing the machine it is helpful to use the Manual Drain Button Press the Drain button to remove water from the integral pump reservoir Mode Button The Mode button is used to switch between standard dehumidifier mode and using the dehumidifier with a duct 1 Power On and Off To power on the machine press the ...

Page 7: ...u press the power key to return to the main menu 3 Defrosting Screen When the unit enters defrosting mode it will show Defrost 000 This is the countdown until defrosting is finished After defrost is completed it will return to the main interface NOTE If you are in a submenu you will not see the countdown until you return to the main interface U N I T O N 0 0 H R S D E F R O S T 0 0 0 If you decide ...

Page 8: ...working time of the dehumidifier The life hours cannot be cleared 3 Inlet Outlet Temperatures I N L E T O U T L E T 0 0 0 0 0 0 0 0 INLET00 00 describes the temperature of the air inlet OUTLET00 00 describes the temperature of the air outlet 4 Humidistat Mode On this screen you can switch from using the humidity set point to continuous mode H U M I D I S T A T M O D E O N When the display shows ON ...

Page 9: ...From this screen you can choose your preferred language Press the button to switch between German Spanish and English 7 Language T E M P U N I T S C L A N G U A G E E N G L I S H 8 Coil Temperature C O I L T E M P 0 0 0 C This screen shows the current temperature of the coils If the temperature is below zero it will show 9 Compressor Current C O M P R S S C U R R E N T 0 0 0 A This screen shows th...

Page 10: ... filter mesh by vacuuming it or washing with warm water no soap or cleaners Gently shake the filter dry then reinsert it 5 For a Carbon or HEPA Filter If there is dirt or buildup replace filter Removing the Housing 1 Remove the screws on the housing 2 Extraction screen Coil Maintenance Once per year clean the coils with an approved coil cleaner Coil cleaner should be a self rinsing foaming cleaner su...

Page 11: ...ou can still use the manual pump button If the actual temperature is much higher than 33 F replace the sensor HI Error AHl error code will appear if the temperature sensor detects the incoming air is above the operating temperature range 45 The unit will not work with a Hl code however you can still use the manual pump button If the actual temperature is much lower than 113 F replace the sensor An...

Page 12: ...or wire is connected at both ends if no issues are visible the sensor may be faulty Verify that the pump is properly installed and functioning If so unplug the unit for two minutes then restart Increase the room temperature so it is within operating range above 33 8 If er ror still displays check sensor Decrease the room temperature so it is within operating range below 110 If er ror still display...

Page 13: ...ginal warranty period continues to applies until meet its deadline All warranty benefits apply to the original owner only Warranty cannot be transferred or assigned 1 YEAR FROM DATE OF PURCHASE Alorair Solitions warrants the dehumidifier will operate free of defects in workman ship and materials At it s discretion Alorair will repair or replace any malfunctioning components free of charge excluding ...

Page 14: ...ILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRAN TIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ALORAIR SOLUTIONS S TOTAL I IABILITY REGARDLESS OF NATURE OF CLAIM SHALL NOT EXCEED ORIGINAL PURCHASE PRICE OF THE PRODUCT IF A PRODUCT OR COMPONENT IS REPLACED WHILE UNDER WARRANTY THE APPLICABLE WARRANTY PERIOD SHALL NOT ...