background image

Integral Pump Maintenance

NOTE:

 This pump requires routine maintenance that is not covered by your 1 year parts 

warranty. Only a defective pump will be repaired or replaced under the warranty.

As with all pumps, preventative maintenance is necessary to prevent issues from dirt 

and slime that may accumulate in the drain system. This includes the drain pan, hose 

to the condensate pump, pump reservoir, pump head, float assembly, and discharge 

tubing

The pump is designed with quick connection construction, making it easy to access the 

pump and components for service and maintenance.

To Remove Pump from Reservoir:

1. Unplug the unit.

2. Open the back housing as shown on page 12.

3. Remove the condensate tube from the pump.

4. Use the quick connect fittings to disconnect the main power and float switch electrical cables.

5. Use a flathead screw driver to gently pry the the pump off the reservoir.

At least once per year, clean your pump system.

Basic Pump Cleaning:

1. Press the pump button (PURGE) to drain any water from reservoir.

2. Disconnect power to the dehumidifier.

3. Mix a 16 oz cleaning solution of one of the following: 1 oz bleach / 15 oz water or 4 oz 

white vinegar / 12 oz water. Pour the solution into the drain tray at the base of the coils.

NOTE:

 If you get any cleaning solution on the coils, flush with water

4. Allow cleaning solution to soak for 15 minutes.

5. Reconnect power to dehumidifier.

6. Pour clean water into reservoir so the pump activates twice (about 16-32 oz. water).

7. Repeat if needed or refer to Advanced instructions.

.

Access screws for electrical

compartment

Cover

Pump

Summary of Contents for STORM PRO

Page 1: ...E INSTRUCTIONS User sManual AlorAir SolutionslNC Add 2048 E Francis st Ontario Ca91761 Tel 1 888 990 7469 E mail sales alorair com STORM ULTRA DEHUMIDIFIER Note as we keep upgrading our product we res...

Page 2: ......

Page 3: ...y off press PURGE button to confirm drain reservoir is empty After the pump has finished operation unplug the power cord and relocate the unit to the desired position If the inside of the machine has...

Page 4: ...Table of Contents Introduction Unit Overview LCD Display Introduction Preparing the Unit for Use Maintenance Repair Storing Your Dehumidifier Troubleshooting Warranty 01 03 04 09 12 14 16 14...

Page 5: ...Serial Number Date of Purchase Customer Service For additional questions concerning the operation fo your dehumidifier please Contact your installing contractor Contact AlorAir Solutions 1 888 990 746...

Page 6: ...t least 8 from any obstructions If the unit has been transported in a horizontal position allow it to sit in an upright position for at least 30 minutes before operating Do not use dehumidifier in an...

Page 7: ...Rear View Storm Pro Dehumidifier Storm Ultra Dehumidifier Air Inlet Air Filter Handle Wheel Front Cover Air Outlet LCD Display Air Inlet Air Filter Handle Wheel Front Cover Air Outlet Drain Tube Conne...

Page 8: ...ation is displayed when the machine is working Refers to the working time which is defined as the time from starting up to shutting down including the defrost time during the period and the standby ti...

Page 9: ...e is the accumulation of each working time hours in hours Press the mode key select to confirmation key and the total working time will be cleaned after 3 seconds 3 Dehumidification status submenu int...

Page 10: ...6...

Page 11: ......

Page 12: ......

Page 13: ...Quick Connection to Drain Tube Quick Connection...

Page 14: ...15...

Page 15: ...bstacles on the filter should be removed regularly You may need to clean and replace the filter Step 1 Unplug the unit 2 Remove the filter by sliding it upward from the bottom byhand to remove it 3 Ch...

Page 16: ...ce 1 Remove the bottom two screws on the front of the machine Remove the bottom two screws on the front of the machine 2 Remove the upper two screws on the back of the machine 3 Take off the casing Re...

Page 17: ...ensate tube from the pump 4 Use the quick connect fittings to disconnect the main power and float switch electrical cables 5 Use a flathead screw driver to gently pry the the pump off the reservoir At...

Page 18: ...re through the discharge tubing Mix another batch of cleaning solution then pour it slowly into drain pan under evaporator coil and allow it to clean the hose from pan to pump This process can be stop...

Page 19: ...ation Error Problem with Pump Room Temperature is below 33 8 Room Temperature is above 110 Refrigerant Leak Verify that both ends of the Power cord are plugged in Reset power Clean the filter Clear th...

Page 20: ...ump is operational by pressing the drain button Verify that the pump energizes and de energizes properly Additionally check to see if any water purged from the system 3 If you haven t cleaned the syst...

Page 21: ...during or after the warranty period You may be responsible for the shipping charge to bring the product to the manufacturer for service To receive warranty service the purchaser must contact ALORAIR a...

Page 22: ......

Reviews: