background image

DEHUMIDIFIERS

-7

-

T

i m

e

 

O

0 0

0 5

f

f

O

0

0

0

0

0

0

I

1

1

Time remaining to Auto Closing

Time remaining tocirculate status

7

 

 

Air purifiers work status 

1) 

Display : Power On ( powered on ) The second line shows : Purify ( purification ) . After 

power Press )

P

P

o w e

o n

u r

i

f

y

2) 

disappears after displaying the main interface )

The machine work is displayed : Purify On ( removal start ) , ( 2 seconds after the display 

3) 

The  main  screen  displays  :  the  first  line  ,  Inlet  20  ℃  60%  (  inlet  air  temperature  (in 

default ℃), into the wind and humidity ) , the second line , purifying ( purification ) .

P

o n

u r

i

f

y

I

n

l

e

t

 

3 2 ℃

7 6 %

Second screen display options:

or

P u r

i

f

y

n g

i

Or set humidity

H u m i

S e

t

3 5 %

.

J

o b

T

 

0 0

0 4

Turn off the machine after the show : purif off ( purification closed )

P

o

f

f

u r

i

f

y

DEHUMIDIFIERS

J o b

T

 

0 0

0 0

L

f

e

i

.

H

Second screen display options:

or

or

0 0

0

0

H u m i

T

i m e r

T e m p U 

R

H u m i

R

S

e

t

t

i

n g

3 5 %

( 1 ) The Humidity Setting (Humid)

a. Press the Menu (M) button.The screen shows:

b. Press the M button until “Humid” is flashing.  Press “OK” to select this option.The 

screen shows:

8. Operation and Display

Note:  As long as the machine is plugged into power, the settings can be changed.  The unit does not 

have to be operating to change setup.

d. Press the menu key until the humidity  level (bottom left of display)  is flashing  (it will 

either say “Co” for continuous or a number for a specific percentage).

e.  Use  the  Up  or  Down  buttons  to  set  the  machine  to  your  desired  level.Press  the  OK 

Buttonwhen  finished.The  cursor  automatically  moves  toR which  will  be  flashing.Press  OK  to 

confirm or wait 10 seconds and you will automatically return to main screen.

( 2 ) Timer Settings (Timer)

This selection allows you to set a timer for the unit to turn on or turn off.  You can also set up cycle 

timing, which allows you to set up and repeating cycle of specific on and off durations.

a. Press the menu key several times unit the Timer button is flashing.  Press OK button to 

confirm this option.

H u m i

T

i m e

r

T e m p U 

R

-8

-

Summary of Contents for Ironmen 50L

Page 1: ...Ironmen 50L E mail sales alorair com Add North Carolina USA Installation and Operations Manual ALORAIR ALORAIR Registrate by scanning...

Page 2: ...f purchase so you can identify your unit when seeking assistance NOTE data label on back of unit includes serial number DEHUMIDIFIERS Contact your installing contractor Email sales alorair com please...

Page 3: ...ute prior to shutting off 2 Purificaction Button P Press air purification function is activated the compressor does not work after entering the mode the fan work timing temperature scale and set the h...

Page 4: ...nd humidity On the second line Job T working time and Humidity Setpoint are displayed on an alternating basis I n l e t 3 2 7 6 The contents of the second line alternateevery 10 sec 5 DEHUMIDIFIERS or...

Page 5: ...e t t i n g 3 5 1 The Humidity Setting Humid a Press the Menu M button The screen shows b Press the M button until Humid is flashing Press OK to select this option The screen shows 8 Operation and Di...

Page 6: ...then turn off 3 Cycling Timer T I O Selection The third selection T I O lets you set up the machine to cycle on and off during a specific time frame For example you could set the unit to run 8 hours a...

Page 7: ...socket safely and reliably 2 through the Vias on Base and connect it to the water pipe which been fixed on water collector Put External pipe DEHUMIDIFIERS Maintenance and Repair 1 2 a out of the filte...

Page 8: ...e from air inlet or air outlet No Airflow Unit is not level Place unit on flat surface in vertical orientation Place unit on flat surface in vertical orientation Loud Unusual Noise 1 3 Trouble code E1...

Page 9: ...labor including but not limited to labor to remove and or reinstall any defective part refrigerant or piping Customer may elect to have unit fixed locally in which case required replacement parts will...