background image

-7-

-8-

Maintenance and Repair

WARNING!

Be sure to turn off the power before for maintenance to avoid accidents !

Because of the air filter is easy to accumulate dust , blocking the air intake passage , 

thereby  affecting  the  dehumidification 

effect  ,  therefore,  must  be  regularly 

cleaned.

If the machine is in larger dust places, 

should be cleaned once a ~ 5 days .

 If the machine is used in relatively 

clean environment can be cleaned once a 

month.

1. Clean the filter

Filter

DEHUMIDIFIERS

DEHUMIDIFIERS

B.

This machine uses a value consistent with the nameplate power outlet must be 

grounded port.

C.

 Remove the power cord and reliably , securely plugged into a power outlet.

D.

 Make sure the machine 's inlet and outlet is not blocked or blocking other objects. 

Ensure the inlet and outlet of the machine can effectively play the smooth performance of the 

machine and reduce electricity costs .

E. 

Before starting the outlet pipe into a drainage tank or water container.

Use Instructions

1 . " On / Off " Button :

a.Press this 

"       "

Button, 

b.Press this

"       "

button again,the unit will stop running .

※ 

Preferably stand for 10 minutes , so that the remaining water droplets on the 

evaporator flows into the water tanks .

Please unplug the power cord after the machine is turned off to save standby power 

consumption and avoid the risk of accidents .

2 ."Up" and "Down" Button

Used to adjust the set humidity , also used to adjust the timing shutdown and timing for 

the start of the set time.

• Humidity setting adjustment range : 

Between 35 to 90 percent , up or down button 

once for each 1% , when the set humidity < 35% , digital display "C0" enter the continuous 

dehumidification  mode  ,  the  first  power-on  defaults  "50  %."  (  Note  :  Continuous 

dehumidification mode not affected by humidity )

                                        The unit automatically determines whether the current humidity 

reaches the starting condition. Such as to reach the starting, such as the current humidity

is lower than the setting humidity, then do not start, running lights shining.