S.G. Ele ronica S.r.l
- Via E. Ferrari , 28 - 30037 Scorzè (VE) Italy - Tel +39 041 5841973 Fax +39 041 5841979 - www.almot.it - [email protected]
2
3.0 DIP SWITCH FUNCTIONS
DIP SW 1
DIP SW 2
FUNCTION
OFF
OFF
Wind alarm threshold seIng 5 km / h
ON
OFF
Wind alarm threshold seIng 15 km / h
OFF
ON
Wind alarm threshold seIng 25 km / h
ON
ON
Wind alarm threshold seIng 35 km / h
DIP SW
POSIZIONE
FUNCTION
3
OFF
Alarm func=on ac=ve and fixed to 8 minutes (from WIND or RAIN alarm interven=on)
ON
Alarm func=on ac=ve for 10 seconds (from WIND or RAIN alarm interven=on)
OFF
Not used
ON
Reversing of TRANSMITTER command keys
4
4.0 PROGRAMMING FIRST TX MASTER REMOTE (IF NO TX IS PRESENT IN MEMORY)
1) Power on the control
unit
2) The buzzer emit a
prolonged sound
3) Within a few seconds,
press the STOP key of the
TX to be memorized.
4)
the control panel buz-
zer will sound intermiDen-
tly.
5)
PROGRAMMING car-
ried out
1)
With the control unit
powered, press and hold
the P1 buDon for 3 se-
conds and release._
2) The buzzer of the
control unit will emit a
prolonged sound
3)
Within a few seconds,
press the STOP key of the
TX to be memorized.
4) the control panel buzzer
will sound intermiDently.
5)
PROGRAMMING
carried out
4.1 STORAGE OF A TX FROM A CENTRAL 892
BEEEEEEP
BEEEEEEP
BEP-BEP-BEP
BEP-BEP-BEP
4.2 TOTAL
RESET
1) With the control unit powered,
press and hold down the P1 key, the
buzzer will emit a long sound
2)
con=nue to hold down the P1
key un=l you hear the inter-
miDent sound of the buzzer.
Release the P1 buDon
3) Within a few seconds, press the
STOP key of the TX to be memo-
rized.
BEP-BEP-BEP