background image

S.G. Ele ronica S.r.l  

-  Via E. Ferrari , 28  -  30037 Scorzè (VE) Italy  -  Tel +39 041 5841973  Fax +39 041 5841979  -  www.almot.it  -  [email protected]

 

3.0 DIP SWITCH FUNCTIONS

 

DIP SW 1 

DIP SW 2 

FUNCTION 

OFF 

OFF 

Wind alarm threshold seIng 5 km / h 

ON  

OFF 

Wind alarm threshold seIng 15 km / h 

OFF 

ON 

Wind alarm threshold seIng 25 km / h 

ON 

ON 

Wind alarm threshold seIng 35 km / h 

DIP SW  

POSIZIONE 

FUNCTION 

OFF 

Alarm func=on ac=ve and fixed to 8 minutes (from WIND or RAIN alarm interven=on)  

ON 

Alarm func=on ac=ve for 10 seconds (from WIND or RAIN alarm interven=on) 

OFF 

Not used 

ON 

Reversing of TRANSMITTER command keys 

4.0  PROGRAMMING FIRST TX MASTER REMOTE (IF NO TX IS PRESENT IN MEMORY)

 

 

 

 

 

 

1) Power on the control 

unit 

2) The buzzer emit a 

prolonged sound 

3) Within a few seconds, 

press the STOP key of the 

TX to be memorized. 

 4) 

the control panel buz-

zer will sound intermiDen-

tly.

 

5) 

PROGRAMMING car-

ried out

 

 

 

 

 

 

1) 

With the control unit 

powered, press and hold 

the P1 buDon for 3 se-

conds and release._

 

2) The buzzer of the 

control unit will emit a 

prolonged sound

 

3) 

Within a few seconds, 

press the STOP key of the 

TX to be memorized.

 

 4) the control panel buzzer 

will sound intermiDently. 

5) 

PROGRAMMING 

carried out

 

4.1 STORAGE OF A TX FROM A CENTRAL 892

 

BEEEEEEP 

BEEEEEEP 

BEP-BEP-BEP  

BEP-BEP-BEP  

4.2 TOTAL          

RESET

 

 

 

 

1) With the control unit powered, 

press and hold down the P1 key, the 

buzzer will emit a long sound 

2) 

con=nue to hold down the P1 

key un=l you hear the inter-

miDent sound of the buzzer. 

Release the P1 buDon

 

3) Within a few seconds, press the 

STOP key of the TX to be memo-

rized. 

BEP-BEP-BEP  

Reviews: