13. TESTING THE SAUNA HEATER
Turn the temperature control to the desired setting. Generally the heater will be operated with the tempera-
ture control to the “max” setting. Turn the heater “on” according to the TIMER OPERATION instructions on
the previous page. Within 5 minutes you should be able to feel heat from the heater elements when holding
your hand over the heater. (If heater does not heat, refer to troubleshooting information on the following
page.) Be sure to let the sauna heat for at least one hour before using the sauna.
11.
Mount the metal temp sensor
housing vertically on the wall and
12” to the right or left of the heat-
er.
For barrel-shaped saunas:
Mount the housing so that the top
is 4.5” below the upper horizontal
wall support.
For a box-shaped
saunas:
Mount the housing 15”
down from the ceiling.
12.
Conceal the temp sensor by
mounting the sensor cover. Place
the cover over the temp sensor
and mount with a single screw that
is provided. Carefully position the
trim over the sensor cable so that
the cable is concealed within the
groove of the trim piece. Attach
trim to wall with included finish
nails.
Sensor Cover
Ce
d
ar
Tri
m