LIST OF ALARMS

DISPLAY

MEANING

ACTION

FLoV_

Flow setting fault

Check the parameters

FrEQ_

Frequency fault

Check the parameters

COEFF_

Difference between two coefficients is greater than 0,5%

Check the coefficients setup

MEtEr

Problem of metering with the meter

Check the setup

LoW_FLo

HiGH_FL

Flow rate less than the setting minimal flow rate

Flow rate greater than the setting maximal flowrate

Check the hydraulic configuration and the flowing

Check the setup

dAtE

Loss of date and time

Set date and time in metrological mode

GAS

GDh is wet but GDl is dry

Check the hydraulic configuration / Check the detector status

SEnSor1
SEnSor2

High gas detector fault (GDh)

Low gas detector fault (GDl)

Use the maintenance menu to check the status of the detector

CoiL

Loss of pulse transmitter signal

Check the connection with the pulse transmitter

tEMPErA

Temperature less than -20°C or greater than 50°C

Check the temperature sensor (measure and calibration)

diSPLAY

doG

LCD display fault

Fault with card

If steady alarm, substitution of the UNI
If steady alarm, substitution of the UNI

ProGrAM

rAM

Error on the checksum of the metrological data

Saved memory fault

If steady alarm, substitution of the UNI
If steady alarm, substitution of the UNI

MEMoriS

Bad writting into the memory

If steady alarm, substitution of the UNI

FuLL

If a measurement result, not older than 3 months, is about to be 

erased

If steady alarm, substitution of the UNI

oVErFLo

Volume greater than 4 194 304 liters

Reset the device

MEtro_

Configuration loss

If steady alarm, substitution of the UNI

bAttErY

Low battery

Substitution of the batteries

totAL_

Totaliser fault

If steady alarm, substitution of the UNI

dEF_MEM

Loss of backup data concerning the last measurement

If steady alarm, substitution of the UNI

Use the maintenance menu to check the status of the detector

R

E

P

A

R

A

T

O

R

U

S

E

R

LF_HiGH

Flow greater than 20m

3

/h while GDh dry

Check the setup

drY MEt

When using a pump. The volume of gas is greater than the 

minimum measured quantity

Stop metering

dEF_CoM

Communication fault with IRDA link

Check the IRDA link

rECEPt

Check the compatibility

Problem of communication protocol between the calculator- 

indicator UNI and the CTD+ key

Summary of Contents for FLEXICOMPT AUTONOME+

Page 1: ...idate the displayed option Validate a fault Light the display during 10 seconds Reset the volume and record the last measurement data SuPErVi Unloading control Visualization Last measurement Totalisers Memorizing Supervisor Menu Calibration Season Parameters Maintenance OPTION transfer of parameters MEtErin ViSuALi NB1 If it s used with Adblue the FLEXICOMPT AUTONOME must be rinsed with water afte...

Page 2: ...errupted at any time by closing the valve 5000L GASoiL End the unloading 4 Continue with another compartment by moving the FLEXICOMPT AUTONOME 3 Close the valve Alarm GAS 980L Alarm Validate the fault with See list of alarms page 4 APPEARANCE OF A FAULT AND DISPLAY OF AN ALARM DISPLAY THE DELIVERY INFORMATION 13 4 C 41 6m3 h Instantaneous flowrate Temperature with active option 0L diESEL 0L unLEAd...

Page 3: ...f Display the totaliser volume at temperature Vm Vb Display the totaliser converted volume with active option MEtErin OPTION KEY CTD TRANSFER MEASUREMENT DATA MEtErin ViSuALi SuPErVi OPTION KEY CTD TRANSFER MEASUREMENT DATA sub menu trAnSFr 0000L GASoiL totALiS MEtErin trAnSFr CALibrA x4 ConFiG nb_dAYS Transfer the parameters and the measurements results to the key Set the number of days for the t...

Page 4: ...t with card If steady alarm substitution of the UNI If steady alarm substitution of the UNI ProGrAM rAM Error on the checksum of the metrological data Saved memory fault If steady alarm substitution of the UNI If steady alarm substitution of the UNI MEMoriS Bad writting into the memory If steady alarm substitution of the UNI FuLL If a measurement result not older than 3 months is about to be erase...

Reviews: