Alma FLEXICOMPT AUTONOME+ Operating Manual Download Page 1

This document sketches out the main menus (please refer to operating manual MU 7033 EN for further information).

D

o

cu

m

e

n

a

va

ila

b

le

 f

o

so

tw

a

re

 4

3

4

v2

.0

0

FORM DOC 124 A

OPERATING GUIDE

FLEXICOMPT A

GU 7033 EN I

www.alma.alma.fr

USING THE BUTTONS

Come back to the previous stage

- Choose the menu option
- Display the delivery information

- Validate the displayed option
- Validate a fault

Light the display during 10 seconds

Reset  the  volume  and  record  the  last 
measurement data

SuPErVi

Unloading control

Visualization (Last measurement, Totalisers

Memorizing)

Supervisor Menu (Calibration, Season, Parameters, Maintenance, 

OPTION transfer of parameters

)

MEtErin

ViSuALi

NB1: If it’s used with Adblue, the FLEXICOMPT A must be rinsed with water after use
NB2: Since the CTD+ key is not ATEX, it must be used outside potentially explosive area
NB3: Do not plug the USB cable during data transfer.

Summary of Contents for FLEXICOMPT AUTONOME+

Page 1: ...idate the displayed option Validate a fault Light the display during 10 seconds Reset the volume and record the last measurement data SuPErVi Unloading control Visualization Last measurement Totalisers Memorizing Supervisor Menu Calibration Season Parameters Maintenance OPTION transfer of parameters MEtErin ViSuALi NB1 If it s used with Adblue the FLEXICOMPT AUTONOME must be rinsed with water afte...

Page 2: ...errupted at any time by closing the valve 5000L GASoiL End the unloading 4 Continue with another compartment by moving the FLEXICOMPT AUTONOME 3 Close the valve Alarm GAS 980L Alarm Validate the fault with See list of alarms page 4 APPEARANCE OF A FAULT AND DISPLAY OF AN ALARM DISPLAY THE DELIVERY INFORMATION 13 4 C 41 6m3 h Instantaneous flowrate Temperature with active option 0L diESEL 0L unLEAd...

Page 3: ...f Display the totaliser volume at temperature Vm Vb Display the totaliser converted volume with active option MEtErin OPTION KEY CTD TRANSFER MEASUREMENT DATA MEtErin ViSuALi SuPErVi OPTION KEY CTD TRANSFER MEASUREMENT DATA sub menu trAnSFr 0000L GASoiL totALiS MEtErin trAnSFr CALibrA x4 ConFiG nb_dAYS Transfer the parameters and the measurements results to the key Set the number of days for the t...

Page 4: ...t with card If steady alarm substitution of the UNI If steady alarm substitution of the UNI ProGrAM rAM Error on the checksum of the metrological data Saved memory fault If steady alarm substitution of the UNI If steady alarm substitution of the UNI MEMoriS Bad writting into the memory If steady alarm substitution of the UNI FuLL If a measurement result not older than 3 months is about to be erase...

Reviews: